54
Unidrive M400 User Guide
Issue Number: 2
5
Analog input 2
Default function
Frequency reference
Type of input
Unipolar single-ended analog voltage, unipolar single-ended current or digital input
(positive or negative logic).
Mode controlled by....
Pr
07.011
Operating in voltage mode (default)
Full scale voltage range
0 V to +10 V ±3 %
Maximum offset
±30 mV
Absolute maximum voltage range
-18 V to +30 V relative to 0 V
Input resistance
100 k
Ω
Resolution
11 bits
Sample / update period
5 ms
Operating in current mode
Current ranges
0 to 20 mA ±4 %, 20 to 0 mA ±4 %,
4 to 20 mA ±4 %, 20 to 4 mA ±4 %
Maximum offset
250 µA
Absolute maximum applied voltage (reverse bias)
-18 V to +30 V relative to 0 V
Resolution
11 bits
Sample / update period
5 ms
Operating in digital mode
Logic mode controlled by…
Pr
08.010
Absolute maximum applied voltage range
-18 V to +30 V relative to 0 V
Impedance
6.8 k
Ω
Input threshold
10 V ±0.8 V from IEC 61131-2
Sample / update period
2 ms when routed to destinations Pr
06.035
or Pr
06.036
, otherwise 6 ms.
6
0V common
Function
Common connection for all external devices
7
Analog output 1
8
Analog output 2
Terminal 7 default function
Frequency output
Terminal 8 default function
Motor active current
Type of output
Unipolar single-ended analog voltage, unipolar single-ended current or digital output.
Mode controlled by…
Pr
07.021,
Pr
07.024
Operating in voltage mode (default)
Voltage range
0 to +10 V ±5 %
Maximum offset
15 mV
Minimum load resistance
500
Ω
Protection
Short circuit relative to 0 V
Operating in current mode
Current ranges
0 to 20 mA ±4 %,
4 to 20 mA ±4 %
Maximum load resistance
500
Ω
Operating in digital output mode
Nominal maximum output current
50 mA
Voltage range
0 V to +24 V
Common to all modes
Resolution
0.1 %
Sample / update period
5 ms