VM_DRIVE_CURRENT
Range applied to parameters showing current in A
Units
A
Range of [MIN]
-9999.99 to 0.00
Range of [MAX]
0.00 to 9999.99
Definition
VM_DRIVE_CURRENT[MAX] is equivalent to the full scale (over current trip level) for the drive and is given by
Full
Scale Current Kc
(11.061).
VM_DRIVE_CURRENT[MIN] = - VM_DRIVE_CURRENT[MAX]
VM_DRIVE_CURRENT_UNIPOLAR
Unipolar version of VM_DRIVE_CURRENT
Units
A
Range of [MIN]
0.00
Range of [MAX]
0.00 to 9999.99
Definition
VM_DRIVE_CURRENT_UNIPOLAR[MAX] = VM_DRIVE_CURRENT[MAX]
VM_DRIVE_CURRENT_UNIPOLAR[MIN] = 0.00
VM_HIGH_DC_VOLTAGE
Range applied to parameters showing high DC voltage
Units
V
Range of [MIN]
0
Range of [MAX]
0 to 1500
Definition
VM_HIGH_DC_VOLTAGE[MAX] is the full scale d.c. link voltage feedback for the high d.c. link voltage measurement
which can measure the voltage if it goes above the normal full scale value. This level is drive voltage rating dependent.
See Table 11-4
VM_HIGH_DC_VOLTAGE[MIN] = 0
VM_LOW_UNDER_VOLTS
Range applied the low under-voltage threshold
Units
V
Range of [MIN]
205
Range of [MAX]
205 to 1150
Definition
Summary of Contents for Unidrive M400