Unidrive M702 User Guide
161
Issue Number: 3
03.038
P1 Device Type
AB (0), FD (1), FR (2), AB Servo (3), FD Servo (4),
FR Servo (5), SC (6), SC Hiperface (7), EnDat (8),
SC EnDat (9), SSI (10), SC SSI (11), SC Servo (12),
BiSS (13), Resolver (14), SC SC (15),
Commutation Only (16)
AB (0)
AB Servo (3)
RW
Txt
US
03.039
P1 Termination Select
0 to 2
1
RW Num
US
03.040
P1 Error Detection Level
0000 to 1111
0000
0001
RW
Bin
US
03.041
P1 Auto-configuration Select
Disabled (0) or Enabled (1)
Enabled (1)
RW
Txt
US
03.042
P1 Feedback Filter
Disabled (0), 1 (1), 2 (2), 4 (3), 8 (4), 16 (5) ms
Disabled (0)
RW
Txt
US
03.043
P1 Maximum Reference
0 to 50000 rpm
1500 rpm
3000 rpm
RW Num
US
03.044
P1 Reference Scaling
0.000 to 4.000
1.000
RW Num
US
03.045
P1 Reference
±100.0 %
RO
Num ND NC PT
FI
03.046
P1 Reference destination
0.000 to 59.999
0.000
RW Num DE
PT
US
03.047
P1 SSI Incremental Mode
Off (0) or On (1)
Off (0)
RW
Bit
US
03.048
P1 SSI Binary Mode
Off (0) or On (1)
Off (0)
RW
Bit
US
03.049
P1 Additional Power-up Delay
0.0 to 25.0 s
0.0 s
RW Num
US
03.050
P1 Feedback Lock
Off (0) or On (1)
Off (0)
RW
Bit
US
03.051
P1 Linear Feedback Select
Off (0) or On (1)
Off (0)
RW
Bit
US
03.052
P1 Linear Comms Pitch
0.001 to 100.000
0.001
RW Num
US
03.053
P1 Linear Line Pitch
0.001 to 100.000
0.001
RW Num
US
03.054
P1 Linear Comms And Line Pitch Units
millimetres (0) or micrometres (1)
millimetres (0)
RW
Txt
US
03.055
P1 Pole Pitch
0.01 to 1000.00 mm
10.00 mm
RW Num
US
03.056
P1 Feedback Reverse
Off (0) or On (1)
Off (0)
RW
Bit
US
03.057
P1 Normalization Turns
0 to 16
16
RO
Num
US
03.058
P1 Normalized Position
-2147483648 to 2147483647
RO
Num ND NC PT
03.059
P1 Normalized Marker Position
-2147483648 to 2147483647
RO
Num ND NC PT
03.060
P1 Calculation Time
0 to 20 µs
5 µs
RW Num
US
03.061
P1 Recovery Time
5 to 100 µs
30 µs
RW Num
US
03.062
P1 Line Delay Time
0 to 5000 ns
RW Num ND NC PT US
03.063
P1 Low Speed Update Rate Active
Off (0) or On (1)
RO
Bit
ND NC PT
03.064
P1 Encoder Protocol Detected
None (0), Hiperface (1), EnDat 2.1 (2),
EnDat 2.2 (3), BiSS (4)
RW
Txt
ND NC PT
03.065
P1 Resolver Poles
2 Pole (1) to 8 Pole (4)
2 Pole (1)
RW
Txt
US
03.066
P1 Resolver Excitation
6kHz (0), 8kHz (1)
6kHz (0)
RW
Txt
US
03.067
P1 User Comms Enable
0 to 1
0
RW Num
US
03.068
P1 User Comms Transmit Register
0 to 65535
0
RW Num
03.069
P1 User Comms Receive register
0 to 65535
0
RW Num
03.070
P1 Position Feedback Signals
000000 to 111111
RO
Num ND NC PT
03.071
P1 Error Detected
Off (0) or On (1)
RW
Bit
ND NC PT
03.075
Initialise Position Feedback
Off (0) or On (1)
Off (0)
RW
Bit
NC
03.076
Position Feedback Initialized
0000000000 to 1111111111
0000000000 RO
Bin
NC PT
03.078
Sensorless Mode Active
Off (0) or On (1)
RO
Bit
ND NC PT
03.079
Sensorless Mode Filter
4 (0), 8 (1), 16 (2), 32 (3),
64 (4) ms
4 (0) ms
RW
Txt
US
03.080
Sensorless Position
-2147483648 to 2147483647
RO
Num ND NC PT
03.083
Full Motor Object Nameplate Transfer
Off (0) or On (1)
Off (0)
RW
Bit
US
03.085
Encoder Simulation Source
0.000 to 59.999
3.016
0.000
RW Num
PT
US
03.086
Encoder Simulation Status
None (0), Full (1), No Marker Pulse (2)
RO
Txt
ND NC PT
03.087
Encoder Simulation Sample Period
0.25 (0), 1 (1), 4, (2), 16 (3) ms
4 (2) ms
0.25 (0) ms
RW
Txt
US
03.088
Encoder Simulation Mode
Hardware (0), Lines Per Rev (1), Ratio (2), SSI (3)
Lines Per
Rev (1)
Hardware (0)
RW
Txt
US
03.089
Encoder Simulation Hardware Divider
0 to 7
0
RW Num
US
03.090
Encoder Simulation Hardware Marker Lock
Off (0) or On (1)
Off (0)
RW
Bit
US
03.091
Encoder Simulation Incremental Mode Select
Off (0) or On (1)
On (1)
Off (0)
RW
Bit
US
03.092
Encoder Simulation Output Lines Per
Revolution
1 to 16384
1024
4096
RW Num
US
03.093
Encoder Simulation Numerator
1 to 65536
65536
RW Num
US
03.094
Encoder Simulation Denominator
1 to 65536
65536
RW Num
US
Parameter
Range
Default
Type
OL
RFC-A
RFC-S
OL
RFC-A
RFC-S
Summary of Contents for Unidrive M702
Page 283: ......
Page 284: ...0478 0002 03 ...