Parameter
Range( )
Default( )
Type
OL
RFC-A
RFC-S
OL
RFC-A
RFC-S
05.001
Output Frequency
±VM_SPEED_
FREQ_REF
±2000.0 Hz
RO
Num
ND
NC
PT
FI
05.002
Output Voltage
±VM_AC_VOLTAGE V
RO
Num
ND
NC
PT
FI
05.003
Output Power
±VM_POWER kW
RO
Num
ND
NC
PT
FI
05.004
Motor Rpm
±180000 rpm
RO
Num
ND
NC
PT
FI
05.005
DC Bus Voltage
±VM_DC_VOLTAGE V
RO
Num
ND
NC
PT
FI
05.006
Rated Frequency
0.0 to 3000.0 Hz
0.0 to
1667.0 Hz
50Hz: 50.0
60Hz: 60.0
RW
Num
US
05.007
Rated Current
±VM_RATED_CURRENT A
Maximum Heavy Duty Rating 11.032
RW
Num
RA
US
05.008
Rated Speed
0 to 180000 rpm
0.00 to 50000.00 rpm
50Hz:
1500.0 rpm
60Hz:
1800.0 rpm
50Hz:
1500.00
rpm
60Hz:
1750.00
rpm
3000.00 rpm
RW
Num
US
05.009
Rated Voltage
±VM_AC_VOLTAGE_SET
200V drive: 230 V
50 Hz - 400V drive: 400 V
60 Hz - 400V drive: 460 V
575V drive: 575 V
RW
Num
RA
US
05.010
Rated Power Factor
0.000 to 1.000
0.850
RW
Num
RA
US
05.011
Number Of Motor Poles
Automatic (0) to 480 Poles (240)
Automatic (0)
6 Poles (3)
05.012
Autotune
0 to 2
0 to 3
0 to 4
0
RW
Num
NC
05.013
OL: Dynamic V To F Select
Off (0) or On (1)
Off (0)
RW
Bit
US
RFC-A Flux Optimization Select
Off (0) or On (1)
Off (0)
RW
Bit
US
05.014
OL: Open-loop Control Mode
Ur S (0), Ur (1),
Fixed (2), Ur Auto
(3), Ur I (4), Square
(5), Current 1P (6)
Ur I (4)
RW
Txt
US
RFC: Action On Enable
None (0),
Phase (1),
Phase Init (2)
None (0)
05.015
Low Frequency Voltage Boost
0.0 to 25.0 %
3.0 %
RW
Num
US
05.016
Motor Parameter Adaptive Control
0 to 2
0
RW
Num
US
05.017
Stator Resistance
0.000000 to 1000.000000
Ω
0.000000
Ω
RW
RA
US
05.018
Maximum Switching Frequency
0 to VM_SWITCHING_FREQUENCY kHz
3 kHz (1)
6 kHz (3)
RW
Txt
RA
US
05.019
High Stability Space Vector Modulation
Off (0) or On (1)
Off (0)
RW
Bit
US
05.020
Quasi-square Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
05.022
Enable High Speed Mode
Off (0) or On (1)
Off (0)
RW
Bit
US
05.023
DC Bus Voltage High Range
±VM_HIGH_DC_VOLTAGE V
RO
Num
ND
NC
PT
05.024
OL: Transient Inductance
0.000 to 500.000 mH
0.000 mH
RW
Num
RA
US
RFC-A: Transient Inductance
0.000 to 500.000 mH
0.000 mH
RW
Num
RA
US
RFC-S: Ld
0.000 to 500.000 mH
0.000 mH
RW
Num
RA
US
05.025
Stator Inductance
0.00 to 5000.00 mH
0.00 mH
RW
Num
RA
US
05.026
High Dynamic Performance Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
05.027
Enable Slip Compensation
Off (0) or On (1)
On (1)
RW
Bit
US
05.028
Flux Control Compensation Disable
Off (0) or On (1)
Off (0)
RW
Bit
US
05.029
Saturation Breakpoint 1
0.0 to 100.0 %
50.0 %
RW
Num
US
05.030
Saturation Breakpoint 3
0.0 to 100.0 %
75.0 %
RW
Num
US
05.031
Voltage Controller Gain
1 to 30
1
RW
Num
US
05.032
Torque Per Amp
0.00 to 500.00 Nm/A
1.60 Nm/A
RO
Num
ND
NC
PT
05.034
Percentage Flux
0.0 to 150.0 %
RO
Num
ND
NC
PT
05.035
Auto-switching Frequency Change Disable
Enabled (0), Disabled (1), No Ripple Detect (2)
Enabled (0)
RW
Txt
US
05.036
Auto-switching Frequency Step Size
1 to 2
2
RW
Num
US
05.037
Switching Frequency
2 kHz (0), 3 kHz (1), 4 kHz (2), 6 kHz (3),
8 kHz (4), 12 kHz (5), 16 kHz (6)
RO
Txt
ND
NC
PT
05.038
Minimum Switching Frequency
0 to VM_MIN_SWITCHING_FREQUENCY kHz
2 (0) kHz
RW
Txt
US
05.039
Maximum Inverter Temperature Ripple
0.0 to 10.0
1.0
RW
Num
US
05.040
Spin Start Boost
0.0 to 10.0
1.0
RW
Num
US
05.042
Reverse Output Phase Sequence
Off (0) or On (1)
Off (0)
RW
Bit
US
05.044
Stator Temperature Source
An In 3 (0), User (1), P1 Drive (2), P1 Slot 1 (3),
P1 Slot 2 (4), P1 Slot 3 (5), P1 Slot 4 (6)
An In 3 (0)
RW
Txt
US
05.045
User Stator Temperature
-50 to 300 °C
0 °C
RW
Num
05.046
Stator Temperature
-50 to 300 °C
RO
Num
ND
NC
PT
05.047
Stator Temperature Coefficient
0.00000 to 0.10000 °C
-1
0.00390 °C
-1
RW
Num
US
05.048
Stator Base Temperature
-50 to 300 °C
0 °C
RW
Num
US
Summary of Contents for Unidrive M702