5.6 Changing the operating mode
Changing the operating mode returns all parameters to their default
value, including the motor parameters.
User security status
(00.049) and
User security code
(00.034) are not affected by this procedure.
Procedure
Use the following procedure only if a different operating mode is
required:
1. Ensure the drive is not enabled, i.e. terminals 11 and 13 are open or
Pr
06.015
is Off (0)
2. Enter either of the following values in Pr
mm.000
, as appropriate:
1253 (50 Hz AC supply frequency)
1254 (60 Hz AC supply frequency)
3. Change the setting of Pr
0.048
as follows:
The figures in the second column apply when serial communications are
used.
4. Either:
•
Press the red
reset button
•
Toggle the reset digital input
•
Carry out a drive reset through serial communications by setting
Pr
10.038
to 100.
Entering 1253 or 1254 in Pr
mm.000
will only load defaults if the setting
of Pr
00.048
has been changed.
5.7 Saving parameters
When changing a parameter in Menu 0, the new value is saved when
pressing the
Enter button to return to parameter view mode from
parameter edit mode.
If parameters have been changed in the advanced menus, then the
change will not be saved automatically. A save function must be carried
out.
Procedure
1. Select ‘Save Parameters'* in Pr
mm.000
(alternatively enter a value
of 1000* in Pr
mm.000
)
2. Either:
•
Press the red
reset button
•
Toggle the reset digital input, or
•
Carry out a drive reset through serial communications by setting
Pr
10.038
to 100
* If the drive is in the under voltage state (i.e. when the control terminal 9
and 10 are being supplied from a low voltage DC supply) a value of 1001
must be entered into Pr
mm.000
to perform a save function.
5.8 Restoring parameter defaults
Restoring parameter defaults by this method saves the default values in
the drives memory.
User security status
(00.049) and
User security code
(00.034) are not affected by this procedure.
Procedure
1. Ensure the drive is not enabled, i.e. terminals 11 and 13 are open or
Pr
06.015
is Off (0)
2. Select 'Reset 50 Hz Defs' or 'Reset 60 Hz Defs' in Pr
mm.000
.
(alternatively, enter 1233 (50 Hz settings) or 1244 (60 Hz settings) in
Pr
mm.000
).
3. Either:
•
Press the red
reset button
•
Toggle the reset digital input
•
Carry out a drive reset through serial communications by setting
Pr
10.038
to 100
5.9 Parameter access level and security
The parameter access level determines whether the user has access to
Menu 0 only or to all the advanced menus (Menus 1 to 41) in addition to
Menu 0.
The User Security determines whether the access to the user is read
only or read write.
Both the User Security and Parameter Access Level can operate
independently of each other as shown in Table 5-8.
Table 5-8 Parameter access level and security
The default settings of the drive are Parameter Access Level Menu 0
and user Security Open i.e. read / write access to Menu 0 with the
advanced menus not visible.
Pr 00.048 setting
Operating mode
1
Open-loop
2
RFC-A
3
RFC-S
NOTE
User
security
status
(11.044)
Access level
User
security
Menu 0
status
Advanced
menu status
0
Menu 0
Open
RW
Not visible
Closed
RO
Not visible
1
All Menus
Open RW
RW
Closed
RO
RO
2
Read-only
Menu 0
Open
RO
Not visible
Closed
RO
Not visible
3
Read-only
Open
RO
RO
Closed
RO
RO
4
Status only
Open
Not visible
Not visible
Closed
Not visible
Not visible
5
No access
Open
Not visible
Not visible
Closed
Not visible
Not visible