Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menu 11
Unidrive SP Advanced User Guide
213
Issue Number: 10 www.controltechniques.com
Gives the type/mode of the data block selected with Pr
11.37
as shown below.
Gives the version number of the data block. This is intended to be used when data blocks are used as drive macros. If a version number is to be
stored with a data block this parameter should be set to the required version number before the data is transferred. Each time Pr
11.37
is changed by
the user the drive puts the version number of the currently viewed data block in this parameter.
Gives the checksum of the data block, space left on the card, the total space on the card for the card flags see Pr
11.37
for details.
Sets the timeout for the drive display to revert to status mode from edit mode following no key presses. Although this parameter can be set to less
than 2s, the minimum timeout is 2s.
Pr 11.38 String
Type/mode
0
FrEE
Value when Pr
11.37
= 0
1
3C.SE
Commander SE mode parameter file (not used)
2
3OPEn.LP
Open-loop mode parameter file
3
3CL.VECt
Closed-loop vector mode parameter file
4
3SErVO
Servo mode parameter file
5
3REGEn
Regen mode parameter file
6-8
3Un
Unused
9
4C.SE
Commander SE mode difference from default file (not used)
10
4OPEn.LP
Open-loop mode difference from default file
11
4CL.VECt
Closed-loop vector mode difference from default file
12
4SErVO
Servo mode difference from default file
13
4REGEn
Regen mode difference from default file
14-16
4Un
Unused
17
LAddEr
Onboard Application Lite user program file
18
Option
A file containing user defined data (normally created by an SM-
Applications Solutions Module)
11.39
SMARTCARD data version
Drive modes
Open-loop, Closed-loop, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
Range
Open-loop, Closed-loop, Servo, Regen
0 to 9,999
Default
Open-loop, Closed-loop, Servo, Regen
0
Update rate
Background read/write
11.40
SMARTCARD data checksum
Drive modes
Open-loop, Closed-loop, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
1
Range
Open-loop, Closed-loop, Servo, Regen
0 to 65,335
Update rate
Background write
11.41
Status mode time-out
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0 to 250 s
Default
Open-loop, Closed-loop vector, Servo,
Regen
240
Update rate
Background read
Summary of Contents for unidrive sp