5.17.2 SM-Resolver
The Solutions Module checks for various errors as shown below.
Table 5-14 Solutions Module error status values for the SM-Resolver
+ This trip can be enabled/disabled by Pr
x.17
.
Figure 5-28 SM-Resolver logic diagram
Error code
Reason for error
0
No fault detected
1
Excitation supply short circuit
2
+Wire-break detect
74
The Solutions Module has overheated.
SM-Applications
Freeze
flag
x.13
x.10
x.15
Equivalent
lines per
revolution
Resolver
excitation
Resolver
poles
Error detection
level
Term Resolver connections
9
SIN LOW
10
SIN HIGH
11
COS LOW
12
COS HIGH
13
REF HIGH (excitation)
14
REF LOW (excitation)
15
0V
16
0V
17
0V
x.39
x.17
Freeze input
SM-Universal
Encoder Plus
x.35
Freeze
revolution
counter
Freeze positional
information
x.36
Freeze
position
9-Way