4 – 1
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391STG
Section 4 • Operation
Operation
All operation (setpoint adjustments, calibrations,
monitoring) of the compressor unit is done through
the Compact Logix PLC. For additional procedural
information, refer to Compact Logix PLC Software
Manual (35391CL).
Oil Inspection
WARNING
When working with LFG, NG or other dangerous
or
fl
ammable gases, ensure there are adequate
ventilation and vapor detectors. Refer to national
fi
re
and building codes. Failure to comply may result in
serious injury or death.
WARNING
Avoid skin contact with any condensate or oil. Wear
rubber gloves and a face shield when working with
condensate or oil. Failure to comply may result in
serious injury or death.
Inspect oil level through sight glasses on the oil
Figure 4-1. Oil Operating Levels
Normal Operating Level
Maximum NON-Operating Level
Minimum Operating Level
separator, see Figure 4-1. Oil Operating Levels. Drain or
fi
ll oil as required. For oil draining and
fi
lling procedures,
refer to Section 5.
Dual Oil Filters
On compressor units equipped with dual oil
fi
lters, only
one
fi
lter should be in operation at a time.
NOTE
During operation, both oil
fi
lter outlet shut-off valves
should be open. This will help minimize the sudden loss
of oil pressure when switching between oil
fi
lters for
servicing.
For further details, refer to Oil Filter Replacement in
Section 5.