4 – 3
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391STG
Section 4 • Operation
• There is an error code
fl
ashing on the actuator’s
circuit board - an attempt to recalibrate should be
made.
• The range of travel is not correct and the command
shaft travel is physically correct.
• The compressor is pulling high amperage, the cali-
bration of the volume slide should be checked.
• An actuator does not unload below 5%, or an actua-
tor that doesn’t move.
• Something is not working properly such as the actua-
tors, RTDs or transducers.
To calibrate optical actuators, continue with the follow-
ing steps:
NOTE
If the compressor unit is starting up for the
fi
rst
time or a new actuator motor has been installed,
leave the power cable and position transmitter cable
disconnected until step 7.
1. Stop compressor unit and allow to cool.
2. Remove screws securing actuator cover to actuator
assembly. As a reference see Figure 4-2.
CAUTION
Wires are attached to the connector on the actuator
cover. Handle actuator cover with care to prevent
damage to wires. Failure to comply may result in
damage to equipment.
3. Carefully lift actuator cover from actuator assem-
bly and tilt towards Turck connectors. Raise cover
high enough to be able to press the blue calibration
button and be able to see the red LED on the top of
assembly.
4. On the main screen of the PLC, press “Menu”, then
“Instrument Calibration” button to enter the in-
strument calibration overview screen, then press
“Calibrate Slides” button to enter the slide calibra-
tion screen, see Figure 4-3.
5. Logging on with high-level access will prompt the
“Enter Slide Calibration Mode” button to appear.
6. Press “Enter Slide Calibration Mode” button to initi-
ate calibration mode. The Slide Calibration button
turns green and Set Max and Set Min buttons ap-
pear, see Figure 4-4.
7. If the compressor unit is starting for the
fi
rst time
or a new actuator was installed, connect connec-
tors of power cable and position transmitter cable
to new actuator.
Figure 4-2. Actuator Assembly
Blue
Calibrate
Button
Red LED
Actuator
Plastic Cover
Actuator
Assembly
View Rotate 180°