A.T.-Temp CryogeniC desuperheATer 

InstallatIon and MaIntenance InstructIons

taBle 1 - standard materials

item

name

material

1•

spray cylinder

sA 182 F304L

2•

nozzle assy

sA 182 F304L

3•

spiral wound packing

pTFe/316L

4•

piston

pTFe 25% reinforced/aluminium bronze*

5•

Fastener ring

sA 182 F304L

7•

stem 

sA 182 F316L

8

seat housing 

sA 182 F304L

9

Body

sA 312 Tp304L

10

Liquid flange

sA 182 F304/F304L dual certified

11

Adaptor

sA 182 F304L

12•

stem bushing lower

Aluminium bronze

13

packing box

sA 182 F304L

14

nut

sA 194 8mA

15•

packing set

pTFe V-rings

16

stud

sA 320 B8 CL.2

17•

stem bushing upper

Aluminium bronze

18

gland plate

sA 182 F304L

19

name plate

Aisi 316

20

Lock nut

stainless steel

21

Coupling

sA 182 F304L

23

securing washer

stainless steel

24

Vapor flange

sA 182 F304/F304L dual certified

25

guiding

pTFe

26

spring

Aisi 631 17-7 ph

27

shoulder bolt

sA 320 B8 CL.2

28

securing washer

stainless steel

29

Flange female

sA 182 F304L

30

Flange male

sA 182 F304L

31

extension pipe

sA 312 Tp304L

32•

piston rings

Aluminium bronze*

notes

* For valve design class 600/900
• recommended spares
other materials are available upon request

certification

The cryogenic A.T.-Temp complies with the rules of Asme B16.34.
en standard flanges are available as an option. if applied within the e.C., 
a certificate of conformity to ped will be issued. The nameplate will bear 
the Ce-marking as applicable for the product.

materials and data of units supplied, may deviate from this brochure. 
please consult order documents in case of doubt.

Figure 11

Summary of Contents for Yarway

Page 1: ...body or use the hoisting lug if provided Do not use the water inlet connection yoke actuator or any of its accessories for lifting Leave the flange covers in place during transportation until ready to install in the pipework When installing the A T Temp Cryogenic desuperheater use gaskets and bolting material in accordance with the relevant piping code for example ASME ANSI B31 3 or EN Place the g...

Page 2: ... Pneumatic or E P positioner Figure 1 Check for damages Check for damages Figure 2 Figure 3 Liquid flange positions Process line Process gas flow Handwheel positions Process line Process gas flow The minimum pipe run required downstream of the A T Temp Cryogenic desuperheater varies with each individual application and would be specified by Yarway at the enquiry stage This straight run is needed t...

Page 3: ...cting to the A T Temp Cryogenic desuperheater mounting flange see Figure 6 Figure 5 Yarway supplies the A T Temp Cryogenic desuperheater as follows Identification number xx 37 xxxxx Fabricated type with non balanced stem xx 47 xxxxx Fabricated type with semi balanced stem and oversized trim all with the spray cylinder tack welded to the body extension pipe Note horizontal orientated A T Temp Cryog...

Page 4: ...rdination between instrument signals and temperature are attained adjustment of the set point can be made and the system transferred to automatic operation It is recommended to record the various process coordinates over a sustained period to verify operation adjusting where necessary Maintenance Note maintenance of the A T Temp Cryogenic desuperheater is straight forward and does not require any ...

Page 5: ...ng wire brush and or honing device Cleanless of the packing area is vital for proper valve sealing Do not use grease or lubricants in combination with PTFE Chevron type packing The actual packing design is mentioned on the project related valve drawing Only ever use genuine Yarway components as they are supplied as matched sets see Figure 9 Disassembly see Figure 8 The A T Temp Cryogenic desuperhe...

Page 6: ... material removed Insert the A T Temp Cryogenic desuperheater into the pipework and check that the nozzle is orientated correctly with the spray with the direction of the gas flow Apply a suitable lubricating compound to the bolts and nuts and tighten evenly in accordance with the manufacturer s recommendations Before connecting the liquid line flush through and check for any contamination or rest...

Page 7: ...plate SA 182 F304L 19 Name plate AISI 316 20 Lock nut Stainless steel 21 Coupling SA 182 F304L 23 Securing washer Stainless steel 24 Vapor flange SA 182 F304 F304L dual certified 25 Guiding PTFE 26 Spring AISI 631 17 7 PH 27 Shoulder bolt SA 320 B8 CL 2 28 Securing washer Stainless steel 29 Flange female SA 182 F304L 30 Flange male SA 182 F304L 31 Extension pipe SA 312 TP304L 32 Piston rings Alumi...

Page 8: ...rred Before placing the A T Temp Cryogenic desuperheater into service stroke valve spindle a few times and inspect other components such as actuator seals etc to ensure correct functioning Follow the procedure for installation as detailed in the operating and maintenance instruction manual Note materials and data of units supplied may deviated from this Instruction Manual Please consult order docu...