TIP
RING
SLEEVE
Diagram #6
FROM TONE
OR VOLUME
ZW INSTRUCTIONS Page 3
If the instrument has a Battery Holder:
If your instrument has a 9 or 18 Volt battery holder you can still
use the EMG Connectors to supply power to the pickups.
Simply cut and strip the wires from the battery clip provided.
Twist the wires together and use the shrink tubing included
to cover the connections. Soldering the wires is the preferred.
9/18 VOLT
BATTERY
HOLDER
BATTERY
NEG (-)
RED to BATTERY BUSS
Soldering to the 152B Panel Jack:
If your instrument has a long Panel Jack like the one below
you will have to solder the output cable as shown.
Ground (Black) to the sleeve
Signal (White) to the Tip
Battery Negative (Black) to the Ring
OUTPUT
T
R
S
NK VOLUME
FROM NECK PICKUP
FROM BRIDGE PICKUP
BR VOLUME
BATTERY
NEG (-)
MASTER
TONE
Diagram #5
2 Pickups
Toggle Style Switch
Volume each Pickup (Volumes are independent)
Master Tone
OUTPUT CABLE
RED
RED
RED
GROUND
BRIDGE P/U
NECK P/U
OUTPUT
1) Install the Pickups and route the Pickup cables to the control cavity.
If the cables are too long, wind up the excess and keep it under the pickup.
2) Mount the Volume and Tone controls into the body.
Plug both pickup cables onto the Volume controls as shown.
Plug a coax cable from the Bridge Volume control to the Pickup Buss (Position 1)
Plug a coax cable from the Neck Volume control to the Pickup Buss (Position 2)
3) Plug a coax cable from the Pickup Buss (position 3) to the Master Tone
control as shown.
4) Strip the insulation from the switch wires and Insert them into the GREEN
Terminal Block and tighten the screws with a small screwdriver.
The Bridge pickup goes to the BR Terminal
The Neck Pickup goes to the NK Terminal
The Output of the switch goes to the O Terminal
If there is a ground wire coming from the switch, insert it into one of the black
terminals on the terminal block.
5) Plug the output cable onto the Tone control and connect the wires to the
output jack by pushing the connectors on as shown.
WHITE wire onto the TIP (T) contact,
BLACK wire onto the SLEEVE (S) contact
BLACK Battery Negative wire onto the RING (R) contact.
6) Plug the RED Wires of the pickups onto the V+ Supply Buss (RED Shroud)
along with the RED of the battery clip. Extra pins are for EMG Accessories.
7) Put the battery in the insulating foam provided and place it securely in the
control cavity.
We suggest that you plug in the instrument and test it before closing the
control cavity.
2 Pickups / Toggle Select Switch / 2 Volumes and Master Tone
Refer to Diagrams #1, #4, and #5
BRIDGE PICKUP (POSITION 1)
NECK PICKUP (POSITION 2)
OUTPUT (POSITION 3)
TO MASTER TONE
Diagram #4
FROM NECK
VOLUME CONTROL
FROM BRIDGE
VOLUME CONTROL
Cover these connections with the
shrink tubing provided.
BLACK to RING terminal
of the Output Jack
RED to BATTERY BUSS
- 9V +