background image

Diagram #9

Diagram #10

ZW INSTRUCTIONS Page 4

OUTPUT

T

R

S

NK VOLUME

FROM NECK PICKUP

FROM BRIDGE PICKUP

BR VOLUME

BATTERY

NEG (-)

NK TONE

BR TONE

Diagram #8

2 Pickups

2 Volume (either volume will act as a master)

2 Tone

Toggle Style Switch

GROUND

BRIDGE P/U

NECK P/U

OUTPUT

RED

RED

RED

OUTPUT CABLE

2 Pickups / Toggle Select Switch / 2  Volumes and 2 Tones)

Refer to Diagrams #1, #7, and #8

 

1) Install the Pickups and route the cables to the control cavity.

     If  the cables are too long, wind up the excess and keep it under the pickup. 

2) Mount the Volume and Tone controls into the body

     Plug both Neck and Bridge pickup cables onto the Volume Controls as shown.

     Plug a coax cable from the Bridge (BR) Volume control to the Pickup Buss

     (Position 1). See Diagram #7

     Plug a coax cable from the Neck (NK) Volume control to the Pickup Buss 

     (Position 2). See Diagram #7

3) Plug a coax cable from the Bridge (BR) Volume control to the Bridge (BR) Tone

     control as shown.

4) Plug a coax cable from the Neck (NK) Volume control to the Neck (NK) Tone

     control as shown.

5) Strip the insulation from the switch wires and Insert them into the GREEN

     Terminal Block and tighten the screws with a small screwdriver.

     The Bridge pickup goes to the BR Terminal 

     The Neck Pickup goes to the NK Terminal

     The Output of the switch goes to the O Terminal

     If there is a ground wire coming from the switch, insert it into one of the black

     terminals on the terminal block.

6) Plug the output cable onto the Pickup Buss (Position 3) and push the connectors

     onto the jack as shown. 

     WHITE wire onto the TIP (T) contact,

     BLACK wire onto the SLEEVE (S) contact

     BLACK Battery Negative wire onto the RING (R) contact.

7) Plug the RED Wires of the pickups onto the V+ Supply Buss (RED Shroud) 

     along with the RED of the battery clip. Extra pins are for EMG Accessories.

8) Put the battery in the foam insulator provided and place it securely in the 

     control cavity. 

     We suggest that you plug in the instrument and test it before closing the 

     control cavity.

B

O

NK

BR

GND

V+

N

O

(OUTPUT)

(INPUT NECK PICKUP)

(BLACK WIRE=SHIELD)

(INPUT BRIDGE PICKUP)

(WHITE WIRE=SIGNAL)

B

O

NK

BR

GND

V+

N

O

SOLDER PADS FOR V+

Soldering to the V+ Buss

If you have an older EMG Pickup without the RED V+ connectors

you can solder to any of the 5 solder pads to supply voltage to 

the pickup. Solder the RED of the battery to any one of these pads

to supply 9V+.

Soldering to the In/Out Buss

If you have an older EMG Pickup without the Black connectors  

you can solder to the pads for pickup inputs. The output can be

routed to the jack or to other EMG Accessories, then to the jack.

RED WIRES

FROM PICKUPS

BATTERY

NEG (-)

RED WIRE

FROM BATTERY

BRIDGE PICKUP (POSITION 1)

NECK PICKUP (POSITION 2)

OUTPUT (POSITION 3) 

FROM NECK

VOLUME CONTROL

FROM BRIDGE 

VOLUME CONTROL

TO OUTPUT JACK

Diagram #7

-  9V  +

-  9V  +