23
English
CODE
POSSIBLE CAUSE
POSSIBLE SOLUTION
27
Extremely light duty cycles
Run unit for longer duty cycles. It is recommended that a
50%-75% average duty cycle be maintained; that is, the air
compressor pump should not run more than 30-45 minutes
in any given hour.
28
Piston rings damaged or worn
Contact an EMGLO factory service center or an EMGLO
authorized service center.
29
Cylinder or piston damaged or worn
Contact an EMGLO factory service center or an EMGLO
authorized service center.
30
Compressor cylinder finish worn
Contact an EMGLO factory service center or an EMGLO
authorized service center.
31
Water in pump oil
Drain oil and refill pump with EMGLO Synthetic Blue
compressor oil.
32
Manual lock unloader lever in
open
position
Rotate manual lock unloader lever to the
closed
perpendicular
position.
33
Regulator open
Rotate the regulator knob counterclockwise to its built-in stop
and push knob in to lock in place.
34
Possible defective motor or starting capacitor
Contact an EMGLO factory service center or an EMGLO
authorized service center.
35
Paint spray on internal motor parts
Contact an EMGLO factory service center or an EMGLO
authorized service center. Do not operate the compressor in
the paint spray area. See flammable vapor warning.