EM12-Z series user manual
16
P1-17
Synchronous motor D-axis
inductance
Inverter power<= 55KW0.01mH
~
655.35mH
Inverter power> 55KW : 0.001mH
~
65.535mH
Auto
tuning
╳
P1-18
Synchronous motor Q axis
inductance
Inverter power<= 55KW:0.01mH
~
655.35mH
Inverter power> 55KW : 0.001mH
~
65.535mH
Auto
tuning
╳
P1-20
Synchronous motor back
electromotive force
0.1V
~
6553.5V
Auto
tuning
╳
P1-27 Number of encoder lines
1
~
65535
1024
╳
P1-28 Encoder type
0:ABZ incremental encoder
1:UVW incremental encode
2:Rotary transformer
3:Sine and cosine encoders
4:Provincial line UVW encoder
0
╳
P1-30
ABZ incremental encoder
phase sequence
0:Forward
1:Reverse
0
╳
P1-31 Encoder installation angle
0.0
~
359.9°
0.0°
╳
P1-32 Reserve
0
0
╳
P1-33 Reserve
0
0
╳
P1-34
Number of pole pairs of
rotary transformers
1
~
65535
1
╳
P1-36
Speed feedback PG
disconnection
Detection time
0.0:on operation
0.1s
~
10.0s
0.0
╳
P1-37 Auto tuning mode selection
0: no operation
1: Asynchronous motor still tunes
2: Asynchronous motor complete tuning
11: Synchronous motor tuning with load
12: Synchronous motor with no-load tuning
0
╳
P2 group The first motor vector control parameters
P2-00 Speed loop proportional gain 1 1
~
100
30
√
P2-01 Speed loop integral time 1
0.01s
~
10.00s
0.50s
√
P2-02 Switching frequency 1
0.00
~
P2-05
5.00Hz
√
P2-03 Speed loop proportional gain 2 1
~
100
20
√
P2-04 Speed loop integral time 2
0.01s
~
10.00s
1.00s
√
P2-05 Switching frequency 2
P2-02
~
Maximum frequency
10.00Hz
√
P2-06 Slip compensation coefficient
50%
~
200%
100%
√
P2-07 Speed loop filter time constant 0.000s
~
0.100s
0.000s
√
P2-08
Vector control over excitation
gain
0
~
200
64
√
P2-09
Upper limit of torque source
selection in speed control mode
0:set by P2-10
1:AI1
2:AI2
3:Potentiometer of keypad
4:PULSE train
5:communication
0
√