EM12-Zseries user manual
25
P8-04 Deceleration time 2
0.0s
~
6500.0s
Per model
√
P8-05 Acceleration time 3
0.0s
~
6500.0s
Per model
√
P8-06 Deceleration time 3
0.0s
~
6500.0s
Per model
√
P8-07 Acceleration time 4
0.0s
~
6500.0s
Per model
√
P8-08 Deceleration time 4
0.0s
~
6500.0s
Per model
√
P8-09 Jumping frequency 1
0.00Hz
~
Maximum frequency
0.00Hz
√
P8-10 Jumping frequency 2
0.00Hz
~
Maximum frequency
0.00Hz
√
P8-11
Jump frequency range
0.00Hz
~
Maximum frequency
0.01Hz
√
P8-12
Dead zone time of
forward to reverse
0.0s
~
3000.0s
0.0s
√
P8-13 Reverse running enable 0: Allow1: Forbidden
0
√
P8-14
Running mode when
setting frequency is less
than the lower limit
frequency
0: Run at lower limit frequency
1: stop
2: Zero speed running
0
√
P8-15 Drop control
0.00Hz
~
10.00Hz
0.00Hz
√
P8-16
Set the cumulative
power-up arrival time
0h
~
65000h
0h
√
P8-17
Set the cumulative
running arrival time
0h
~
65000h
0h
√
P8-18 Start protection selection 0: Disable 1: Enable
0
√
P8-19
Frequency detection
value (FDT1)
0.00Hz
~
Maximum frequency
50.00Hz
√
P8-20
Frequency detection
hysteresis (FDT1)
0.0%
~
100.0%
(
FDT1 voltage level
)
5.0%
√
P8-21
Frequency arrival
detection amplitude
0.0%
~
100.0%
(
Maximum frequency
)
0.0%
√
P8-22
Whether the jump
frequency is valid during
acceleration /
deceleration
0: Invalid
1: Valid
0
√
P8-25
Swtich over point
between
acceleration time 1 to
acceleration time 2
0.00Hz
~
Maximum frequency
0.00Hz
√
P8-26
Swtich over point
between
deceleration time 1 to
deceleration time 2
0.00Hz
~
Maximum frequency
0.00Hz
√
P8-27 Terminal control prior
0: Invalid
1: Valid
0
√
P8-28
Frequency detection
value (FDT2)
0.00Hz
~
Maximum frequency
50.00Hz
√
P8-29
Frequency detection
hysteresis (FDT2)
0.0%
~
100.0%
(
FDT2 voltage level
)
5.0%
√
P8-30
Any arrival frequency
detection value 1
0.00Hz
~
Maximum frequency
50.00Hz
√