background image

TB-6586

 Page 2 of 3

© 2014 DESCO INDUSTRIES, INC.

Employee Owned

EMIT 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website: 

DescoEMIT.com

Installation

SMARTLOG V5™

1.  Mount the ESD Glove Test Fixture next to the SmartLog 

 

V5

 using its mounting tabs located at the top and 

 

bottom.

2.  Connect the included communication cable to 

 

the jack located at the bottom of the ESD Glove 

 

Test Fixture.

3.  Connect the other end of the communication cable 

 

to the External Reader port located on the right-side 

 

of the SmartLog V5

.  No power adapter is needed 

 

for the ESD Glove Test Fixture.  It will draw its 

 

power from the tester.

Figure 2.  Locating the External Reader port on the 
SmartLog V5™

Right Side View

COMBO TESTER X3

1.  Mount the ESD Glove Test Fixture next to the Combo 

 

Tester X3 using its mounting tabs located at the top and 

 

bottom.

2.  Connect the included communication cable to 

 

the jack located at the bottom of the ESD Glove 

 

Test Fixture.

3.  Connect the other end of the communication cable 

 

to the External Reader port located on the bottom of 

 

the 

Combo Tester X3

.  No power adapter is needed 

 

for the ESD Glove Test Fixture.  It will draw its 

 

power from the tester.

Figure 3.  Locating the External Reader port on the 
Combo Tester X3

Bottom View

Operation

SMARTLOG V5™

1.  Initiate the test procedure by identifying yourself to 

  the SmartLog.  This may be done using the keypad, 

  barcode badge scanner or proximity badge reader (if 

  supplied).
2.  Follow the prompt on the SmartLog’s display.
3.  When performing a footwear test, be sure to place 

  both feet on the dual foot plate (one foot per plate).
  When performing a wrist strap test, be sure to 

  completely plug in the wrist cord into the tester’s 

  jack.
4.  Grab the ESD Glove Test Fixture’s electrode to 

  perform a test.  Hold the electrode until the results of 

  the test are displayed on the SmartLog.
  If performing a wrist strap test, and the wrist strap 

  status LEDs do not illuminate, verify that the wrist 

  cord is correctly inserted into the tester.
5.  The relay terminal will activate if the defined tests 

  are passed (if applicable).

Figure 4.  Using the ESD Glove Test Fixture with the 
SmartLog V5™