OTDR SETTING 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
Test Setting: 

Avg.Time,Wave and Refractice Index are the 

same as those in Auto OTDR.

 

Refractive  Index: 

provided  by  optical  cable  or  fiber  manufac  turer.It  is  the  key 

parameter for calculating the distance, and can not be set arbitrarily.

 

Unit:

select the required unit, there are 3 options for mi/km/kft.  

Real Time Test Analyse

Open/Cancel the real Time Test Analyse function at the end 

of real-time test

 

Event Loss Threshold: 

set the loss threshold of connection point, fusion point in the 

link that can be tested, between 0.2dB ~ 30dB, and the default value is 0.2dB. Loss 
value larger than the setting value will be listed in the event list, or it will be ignored. 

Reflectance Threshold: 

set the return loss threshold of the link reflection events that 

can be tested, ranging from 10dB to 60dB, the default value is 40dB.

  

End Loss Threshold: 

set the loss threshold after link that can be tested, ranging from 

1dB to 30dB, the default value is 10dB.  

Auto Save: 

Open/Cancel the Auto Save file function at the end of  real-time test 

OK: 

save the set parameters

 

Default: 

restore factory settings

 

 

 

Summary of Contents for EasySplicer OTDR

Page 1: ...to 300m EasySplicer EasySplicer EasySplicer EasySplicer O O O OTDR TDR TDR TDR Owners Manual Professional instrument for measuring loss and finding faults in Fiber networks Domain Reflectometer Measu...

Page 2: ...TDR LIST 8 EXPERT OTDR Expert Mode 9 OTDR SETTING 10 OTDR FILE SAVE FILES 11 OTDR FILE OPERATION File maintenance 12 EVENT MAP 13 LASER SOURCE 14 OPM OPTICAL POWER METER 15 VFL VISUAL FAULT LOCATOR 16...

Page 3: ...ndinavia AB tries to make the user manual complete and accurate it may contain mistakes and the user uses it solely at his or her own risk EasySplicer OTDR components The following components are incl...

Page 4: ...BRIEF FUNCTION KEYS...

Page 5: ...MAIN MENU Start up Turn ON the instrument and the EasySplicer OTDR will start up in the Main menu Touch the function of Your choice...

Page 6: ...eration functions Screen capture Capture the current interface the picture will be automatically saved in the instrument and the file name is the time when the screenshot is generated Note The laser r...

Page 7: ...IOR and test time Pass Fail settings Avg Loss Thre set the threshold of the max link loss margin Event Loss Thre set the loss threshold of events in the link If it is greater than this threshold it wi...

Page 8: ...ber of events passed numbers failed numbers In the event list NO the order of the current event Type the type of the current event Dis the distance of the current event Loss the loss value of the curr...

Page 9: ...utoTest RealTest Avg Test Wavelength select the test wavelength of OTDR Test range usually choose about 2 times of the length of the optical fiber to be tested Test pulse width 3ns 20000ns optional di...

Page 10: ...loss threshold of connection point fusion point in the link that can be tested between 0 2dB 30dB and the default value is 0 2dB Loss value larger than the setting value will be listed in the event li...

Page 11: ...and press Enter to save the file If the automatic save otdr function is turned on System Settings it will be saved automatically after the test is complete without manual operation Auto save function...

Page 12: ...aintenance OTDR File Operation Press Files to enter the file list Head back to the first page Delete delete the current file or folder Rename change the name of the current file or folder Open open th...

Page 13: ...ent point and the position of breakpoint can be displayed in a graphical form The result is clear and easy to understand The starting point Starting point with launch cable Connected gadgets causing l...

Page 14: ...ive devices and wavelength responsiveness of detectors Open turn on the laser source Wave switch the wavelength the output wavelength is consistent with OTDR Mode switch the modulation frequency of li...

Page 15: ...70 330 1000 2000Hz optical signal Wave switch the working wavelength Reference set current power as reference power CAL enter the user calibration mode and calibrate with the standard light source TWI...

Page 16: ...sured fiber It is suitable for the detection of bare optical fibers jumpers and other high loss sections caused by near end faults and micro bending of optical fibers and cables which can leak red lig...

Page 17: ...are as follows 1 First connect the LS and opm optical interface with standard jumpers Press Open and press Reference after the power is stable 2 Then connect the tested part to LS and opm optical int...

Page 18: ...can withstand voltage and prevent burning and can be directly charged for line finding Ethernet switch router and other weak current equipment with DC voltage less than 60V Start open the RJ45 cable...

Page 19: ...ote module when measuring Standard select different network cable standards Test start cable sequence test Exit exit the cable sequence test and return to the main interface WARNING Please do not test...

Page 20: ...ch different units CAL adjust the test result according to the actual length and display length last test result correction Test start cable length test WARNING Please do not test online ATTENTION The...

Page 21: ...ion Date Time set the instrument date and time Sound turn the touch tone on or off Flashlight turn the flashlight on or off USB connection connect to the computer after opening and transfer data Bluet...

Page 22: ...output port and wipe the connection end face with a special dust free paper towel or cotton swab wetted with alcohol At the same time please cover the dust cap after using the instrument and keep the...

Page 23: ...50ns 80ns 160ns 320ns 500ns 800ns 1us 2us 3us 5us 8us 10us 20us Ranging Accuracy 1m Sample interval 0 005 Test distance Linearity 0 05dB dB Sample Points 6k 128k Sample Resolution 0 05m 8m Loss Resol...