10
5.3 Failure Messages in ESM-3700 Digital Process Indicator
Process Indicator
ESM - 3700
P
AS
ASET
Process Indicator
ESM - 3700
P
AS
ASET
If the equivalent voltage or current applied to
the process input while in
or
parameter
for
user
reading adjustment is
out of the standard scale, this error message
are shown on the display
Example-1:
For process Input type selected as 0-10 V
, If
the applied voltage while in
parameter or
parameter is lower than
0 V
or upper than 10 V
, when the
decrement or increment button is pressed for
saving the analog value this errror message is
shown on the display and applied voltage value
is not saved.
Press any button to clear error
message from the display and turn to the user
reading adjustment analaog value entering
screen
Z
Z
Z
If the difference between the equivalent
voltage or current applied to the process input
while in
and
parameters
for user reading adjustment is lower than the
%50 of the standard scale, this error message
are shown on the display
Example-2:
For process Input type selected as 0-10 V
, If
the difference between the applied voltages in
and
parameters is
lower than the 5 V
, when the decrement or
increment button is pressed for saving the
analog value this errror message is shown on
the display and applied voltage value is not
saved.
Press any button to clear error
message from the display and turn to the user
reading adjustment analaog value entering
screen
Z
Z
ENGLISH