Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter
is 1, internal buzzer starts to operate.
6.4 Failure Messages in ESM-3710-N Temperature Controller
6.3 Operation Graphics of ESM-3710-N
Controller
Temperature
1-If Operating Type Parameter Value = 1 (Cooling),
Switch On Delay After Power On Parameter Value
1 ,
Compressor Stop/Start Time Delay Parameter Value
1 and
Compressor Start/Start Time Delay Parameter Value
1;
³
³
³
Power
Time
Hst
SET
Time
Output
Time
Time
Output
Led
°C
ON
OFF
Temperature
Value
Temperature Control Output
SET
HSt
Time
HSt
HSt
Time
2-If Operating Type Parameter Value = 0 (Heating),
i
In ON/OFF control algorithm, temperature value is tried to keep equal
to set value by opening or closing the last control element. ON/OFF controlled
system, temperature value oscillates continuously. Temperature value’s oscillation
period or amplitude around set value changes according to controlled system. For
reducing oscillation period of temperature value, a threshold zone is formed below or
around set value and this zone is named hysteresis. Action of control output is
described with figures above.