background image

16 

 3.5.1 Proximity Connection

3.5 Input Connection

NOTE-1

1

3

2

4

5

1

2

 V

 

Z

M

a

x

5

0

m

A

0

 V

 

Z

P

A

U

S

E

PROX.

PROX.

R

E

S

E

T

PNP

PNP

PROX.

PNP

S

T

A

R

T

NOTE-1

1

3

2

4

5

1

2

 V

 

Z

M

a

x

5

0

m

A

0

 V

 

Z

P

A

U

S

E

PROX.

PROX.

R

E

S

E

T

NPN

NPN

PROX.

NPN

S

T

A

R

T

=

=

PNP type operation

NPN type operation

NOTE-1 : Sensor supply voltage: 12V

Z

 ± 40%,   50 mA maximum with short circuit 

protection

Summary of Contents for EZM-7735

Page 1: ...r 6 digits Process PV and 6 digits Set SV Value Display Operation with 1 Set Value Reset Pause and Start Inputs Operation with Automatic and Manual Reset NPN PNP Type Operation EZM 7735 72 x 72 DIN Un...

Page 2: ...ce to the system are explained Operation and Parameters In this section user interface of the device how to access to the parameters description of parameters are explained Also in these sections ther...

Page 3: ...3 5 INPUT CONNECTION 3 5 1 PROXIMITY CONNECTION 3 5 2 SWITCH CONNECTION 3 6 RELAY OUTPUT WIRING DIAGRAM 3 7 GALVANIC ISOLATION TEST VALUES OF EZM 7735 PROGRAMMABLE TIMER 4 DEFINITION OF FRONT PANEL A...

Page 4: ...o the following directives 2006 95 EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4...

Page 5: ...control rollers and can be adapted easily to all mechanical construction and automation system Some application fields which they are used are below Standart EZM 7735 Standart Supply Voltage Input 230...

Page 6: ...vered is free from defects in material and workmanship This warranty is provided for a period of two years The warranty period starts from the delivery date This warranty is in force if duty and respo...

Page 7: ...the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit may...

Page 8: ...inch OP SV O2 S2 Timer EZM 7735 RESET P SET OP V S 2 O S2 i T er m Z 735 E M 7 E ET R S P SET Maximum 15 mm 0 59 inch 84 mm 3 31 inch 11 5 1 mm 0 45 inch Front Panel IP65 protection NEMA 4X Panel sur...

Page 9: ...10 2 3 Panel Cut out 9 97 mm 3 82 inch min 69 mm 2 72 inch 69 mm 2 72 inch 97 mm 3 82 inch min...

Page 10: ...at the cut out is the right size 2 Check front panel gasket position 3 Insert the device through the cut out If the mounting clamps are on the unit put out them before inserting the unit to the panel...

Page 11: ...e will not fall while doing the montage The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the front side 2 Insert the mounting clamps to the holes that located top an...

Page 12: ...ing to the system s needs Only qualified personnel and technicians should work on this equipment This equipment contains internal circuits with voltage dangerous to human life There is severe danger f...

Page 13: ...nnel injury Inputs Sensor Supply Voltage Max 50mA PAUSE RESET 12 V Z 0 V Z Supply Voltage Input It must be determined in order 230V V 15 10 50 60Hz 2 3VA 115V V 15 10 50 60Hz 2 3VA 24 V V 15 10 50 60H...

Page 14: ...3 3 View of Device Label 14 a a P N EZM 7735 1 2 3 4 5 18 19 20 21 22 N L 230V V 15 10 50 60Hz 2 3VA 5A 250VV NC C NO 12 V Z Max 50mA 0 V Z Reset Pause Y ca Start...

Page 15: ...ge must be applied to the unit Controlling prevents damages in unit and system and possible accidents as a result of incorrect supply voltage There is no power supply switch on the device So a power s...

Page 16: ...2 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET PNP PNP PROX PNP START NOTE 1 1 3 2 4 5 12 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET NPN NPN PROX NPN START PNP type operation NPN type operation NOTE 1 Senso...

Page 17: ...itch Switch 1 3 2 4 5 PAUSE RESET NOTE 1 Switch Switch NOTE 1 0 V Z 12 V Z Max 50mA 0 V Z 12 V Z Max 50mA Switch START Switch START PNP type operation NPN type operation NOTE 1 Sensor supply voltage 1...

Page 18: ...ammable Counter Supply Voltage 500V V for EZM 7735 3 2000V V for EZM 7735 5 12V Z Sensor Supply Voltage Relay Outout 3 6 Relay Output Wiring Diagram Fuse Load Last Control Element Contactor 5A V T Fus...

Page 19: ...NT Button is used to Reset the Actual Value or increment the digit value that is selected by SHIFTING Button ENTER Button is used for saving all changes to memory and accessing to the parameters SHIFT...

Page 20: ...power is applied to the device software revision number of the controller is on actual value display Then operation screen is observed momentarily illuminated rEu Revision If there is an unexpected s...

Page 21: ...SV O2 S2 OP SV O2 S2 OP SV O2 S2 RESET P SET Operation Screen SET Screen SET Screen SET Screen Operation Screen SET Screen When shift button is pressed 6th digit of SET value starts to flash Press Shi...

Page 22: ...RESET in parameters section At the end of MANUAL RESET if then Count value becomes 0 value If then Count value becomes SET value 4 4 Resetting the Count Value When RESET button is pressed Actual Valu...

Page 23: ...eter flashes Press Enter Button Filter time for Reset Pause and Start Input You can change the p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter...

Page 24: ...he p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter with ENTER button Press Enter Button Press PROG button to exit from programming section with...

Page 25: ...G button to exit from programming section without doing any changes You can change the p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter with ENT...

Page 26: ...26 Continue to press ENTER button for scanning all parameters Time Unit and Scale Selection Operation Screen OP SV O2 S2 OP SV O2 S2 RESET P SET OP SV O2 S2 OP SV O2 S2 RESET P SET...

Page 27: ...me It can be adjusted from to msec 8 PARAMETRELER 5 Program Parameters Time Unit and Scale Selection Hour Minute It can be adjusted from to Minute Second It can be adjusted from to Second Milisecond I...

Page 28: ...es while Start input is active When Start input is passive count value becomes 0 When Manual Reset happens count value becomes 0 value Counting direction P 0 Downcounting When count value reaches the...

Page 29: ...ens count value becomes 0 value Counting is continues while Start input is active When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 O...

Page 30: ...the SET value When Manual Reset happens count value becomes 0 value When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 Value Output P...

Page 31: ...mes 0 value When count value reaches the 0 Value Output Position is changed Actual value is reset automatically If Start input is active then counting starts downcounting at Set value If Output Pulse...

Page 32: ...nput is active then counting starts from 0 value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at SET value Counting process is n...

Page 33: ...ive then counting starts from Set value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at 0 value Counting process is not continue...

Page 34: ...alue reach SET value output position becomes active position and if the Start input is active then count value starts counting from 0 value But SET value is observed in actual value display Counting p...

Page 35: ...until Manual Reset happens When counting value reach 0 value output position becomes active position and if the Start input is active then count value starts counting from Set value But 0 value is ob...

Page 36: ...has not change until Manual Reset happens When counting value reach Set value output position becomes active position If the Start input is active then counting continue over the Set value When Manua...

Page 37: ...sition If output pulse time then output position has not change until Manual Reset happens When counting value reach 0 value output position becomes active position If the Start input is active then c...

Page 38: ...position When manual reset happens count value becomes SET value If the Start input is active then Process starts counting until count value reach SET value When count value reach SET value Output Pos...

Page 39: ...e screen Sensor Type Selection NPN type sensor selected PNP type sensor selected Reset and Set Protection for Front Panel Access Only RESETButton protection is active Actual value can not be reset by...

Page 40: ...play If program password is not 0 while accessing to the program parameters 1 If user does not enter the value correctly operation screen will appear without entering to operator parameters 2 When in...

Page 41: ...t significant digit of the parameter flashes But if the password is not entered flashing of the most significant digit is not realised When PROG button is pressed password entering screen will appear...

Page 42: ...warning and reset the count value press RESETbutton 2 If Actual Value is flashing and counting is stopped It appears if any of the count value is greater than the maximum count value To remove this wa...

Page 43: ...trical Characteristics Rated voltage 16 VZ 5mA Maximum continuous permissible voltage 30 VZ Logic 1 minimum level 3 VZ Logic 0 maximum level 2 VZ Sensor Supply Voltage Electrical Characteristics 12VZ...

Reviews: