30
=
=
Counting direction : 0 --> P (Upcounting)
=
Manual Reset-3.
Device continues to count till manual reset is applied.
(Output Pulse Time is considered.)
When count value reaches the Set Value, Output Position is
changed. If Output Pulse time is not 0, then Output
Position is changed at the end of the Pulse time. If
then Output Position has not change, until Manual Reset happens.
Counting process continues over the SET value.
When Manual Reset happens, count value becomes 0 value. When
Start input is passive, count value becomes “0”.
=
Counting direction : P --> 0 (Downcounting)
=
When count value reaches the 0 Value, Output Position is changed. If
Output Pulse time is not 0, then Output Position is changed
at the end of the Pulse time. If then Output Position
has not change until Manual Reset happens. Counting process
continues under the 0 value.
When Manual Reset happens count value becomes SET value. When
Start input is passive, count value becomes SET value.
=
0
Set
Reset
Output
Output
Start
0
Set
Reset
Çýkýþ
Output
Start