UM-155-290-Limpet User Manual 

 V2.0 

 

6 | 

P a g e

 

 

4.

 

Installing the software 

 

 

Insert the EML USB stick received with the EML Limpet Logger (or download from the EML 
website 

 

www.emltd.net

)

 

Run t

he ‘.exe’ file contained on the

 device or the download. 

 

Follow the instructions to install the software. 

 

After 

installation, run the ‘EML Limpet

 

Logger GUI.exe’ to open the software

5.

 

Configuring the logger 

 

Connect logger to a PC 

 

Connect one end of the serial cable to the Limpet Logger and the other end to a free serial 
USB port on the Computer. 

 

Select  ‘Auto  detect’  on  the  Port  combo  box  then  Press  the  ‘Connect’  button.  This  will 

automatically select the appropriate COM port and connect the logger GUI to it. 

 

Run the ‘Configuration wizard’

 

Press the 

‘Config

 W

izard’

 button.  This guides the user through the main requirements for configuring 

the logger.  These are summarised below: 

 

Clear logger memory 

 

Set date-time 

 

Select measurement unit 

 

Select calibration factor 

 

Select memory mode 

 

Manually configure the logger 

This section describes in more detail the steps carried out in the Configuration Wizard.  For manual 
configuration of the logger, it is recommended that the user carries out the following tasks in order:  

Clear logger memory: 

Press 

‘Clear memory’

 button on the main screen of the software and, if you are sure, press 

‘Yes’ 

when 

prompted. 

This ensures that the new logger configuration makes use of the whole logger memory.  Note that the 
memory must be cleared before a new configuration is loaded.  Therefore, if there are data on the 
logger which are needed, exit the configuration wizard at  this point, download the  data, and then 
return to the configuration wizard. 

Set date-time: 

Automatically  set  the  date-time:

    Press 

‘Auto  set  date

-

time’

  button  on  the  main  screen  of  the 

software. This will set the logger’s time to the PC time.

 

Manually set the date-time:  

Go to 

‘Options’ 

then 

‘Set Date and Time Manually’

.  Use the drop-down 

menus to set the logger’s time manually.

 

Summary of Contents for Limpet

Page 1: ...UM 155 290 Limpet User Manual V2 0 Limpet User Manual...

Page 2: ...rm or by any means electronic or mechanical including photocopying nor may its contents be communicated to a third party without prior written permission of the copyright holder The contents are subje...

Page 3: ...n the Configuration wizard 6 Manually configure the logger 6 Clear logger memory 6 Set date time 6 Select measurement unit 7 Select calibration factor 7 Select memory mode 7 6 Event based memory 7 7 D...

Page 4: ...t The information contained in this manual may not cover all aspects of Limpet applications Please refer to associated equipment manuals or consult papers and technical notes on the EML website www em...

Page 5: ...ontroller a real time clock 2Mbytes of non volatile memory a contact input and a USB port for communication with a computer The Limpet is powered using a 2 3 A 3 6V lithium battery Measurements from a...

Page 6: ...memory Set date time Select measurement unit Select calibration factor Select memory mode Manually configure the logger This section describes in more detail the steps carried out in the Configuratio...

Page 7: ...ll continue indefinitely However whenever the memory capacity is full the oldest data will begin to be overwritten A unique feature of this logger is that if this happens a record of the total rainfal...

Page 8: ...bration Factor Count 07 10 2016 12 03 56 0 200 001 07 10 2016 12 05 02 0 200 001 07 10 2016 12 07 06 0 200 001 Downloading the data Connect the datalogger to the PC using the method outlined in Sectio...

Page 9: ...s recorded within a specified interval are aggregated and recorded as a total number of events within the specified time period Select the Data Conversion tab on the software screen Select the data fi...

Page 10: ...start the aggregations For example the first event in the figure below is recorded at 09 47 28 To aggregate the data to a 5 minute interval starting at 09 50 00 would be a typical approach Rounding 09...

Page 11: ...s been selected by selecting a different port This can be done only if the Limpet GUI is displaying more than one COM port If the Limpet GUI was communicating with the Limpet and has just stop communi...

Page 12: ...crosoft NET Framework 4 0 which is usually installed on most Microsoft Windows OS including Microsoft Windows 7 to Windows 10 Some reasons why a Windows OS may not have Microsoft NET Framework 4 0 An...

Page 13: ...w ftdichip com Drivers D2XX htm The installation guide of FTDI driver for all Window operating system is available on the following link http www ftdichip com Support Documents InstallGuides htm The i...

Reviews: