REPLACEMENT OF THE REGULATOR

WITH A FLOW METER CARTRIDGE

THE NEW TRANSFORMABLE EMMETI LOCKSHIELD CAN BE COMBINED

WITH A FLOW METER CARTRIDGE
• WHILE THE SYSTEM IS RUNNING;

• WITHOUT WATER LOSS;

• SIMPLY AND QUICKLY.

3

NEW DOUBLE REGULATING LOCKSHIELD

EMMETI HAVE EVOLVED A NEW AND SUPERIOR LOCKSHIELD DESIGN. THIS 

ALLOWS EASIER, QUICKER AND MORE ACCURATE ONSITE SETTING OF THE 

CORRECT FLOW. IT IS MORE ACCURATE AT MAINTAINING THE CORRECT LOW 

FLOW, WHEN SET TO A SMALL APERTURE.

YOU NO LONGER NEED TWO SEPARATE TOOLS TO ADJUST TO A SUITABLE 

FLOW RATE. FURTHER, THIS LOCKSHIELD CAN BE UPGRADED ON SITE TO 

BECOME AN INTEGRATED FLOW METER AND LOCKSHIELD.

ADJUST THE LOCKSHIELD AS FOLLOWS:

THE LOCKSHIELD IS SUPPLIED IN THE CLOSED POSITION.

•  REMOVE THE CAP  

• TURN THE CAP OVER, AND, USING THE IMPRESSION INSIDE IT, TURN 

THE ISOLATOR 

 

ANTICLOCKWISE UNTIL REACHING A FULLY OPEN 

POSITION.

• USE A 4 mm  ALLEN KEY CLOSE THE ADJUSTMENT SCREW CLOCKWISE  

, COMPLETELY, UNTIL REACHING THE END OF STROKE.

  THE LOCKSHIELD IS NOW READY FOR FLOW SETTING.

• UNSCREW THE ADJUSTMENT SCREW ANTICLOCKWISE 

, BY THE 

DESIRED NUMBER OF TERMS (PLEASE USE GRAPH ON PAGE 17).

• INSERT THE CAP AGAIN. 

IT  IS  NOW  POSSIBLE  TO  SEAL  THE  CAP  INTO  POSITION  USING  LEAD, 

TAKING ADVANTAGE OF THE HOLES PRESENT IN THE FINS 

 IN ORDER 

TO  FASTEN  DIRECTLY  TO  THE  MANIFOLD,  PLUS  MAKING  TAMPERING 

IMPOSSIBLE.

NOTE:

THE ISOLATOR 

, IS NOT USED FOR CALIBRATION ONLY FOR ISOLATION.

REPLACEMENT OF THE REGULATOR WITH A MEASUREMENT CARTRIDGE:

• CLOSE THE ISOLATOR 

 USING CAP 

. REMOVE THE CLIP WITH A SCREWDRIVER.

• REMOVE THE REGULATOR 

 USING AN ALLEN KEY AND SCREWDRIVER.

• INSERT THE MEASUREMENT CARTRIDGE AND REPLACE THE CLIP.

  PLACE THE WHITE RING NUT OVER THE CARTRIDGE.