CDSA User Manual
Subsequent Upgrade Procedure:
After you have used the EMMSETUP utility for the first time a shortcut “EMM Labs
Update Utility” is installed on the desktop of your PC as well as in the
START>PROGRAMS>EMM Labs folder. There is no need to launch the “emmsetup.exe”
application anymore.
1. Connect your CDSA to the PC via a USB cable
2. Launch “EMM Labs Update Utility” from the desktop of your PC and you should
see the above screen directly.
3. Proceed from here as for first time installation.
IMPORTANT NOTE:
THE ENTIRE UPDATE PROCEDURE CAN TAKE UP TO 1 MINUTE. IT IS IMPORTANT
THAT YOU DO NOT INTERRUPT POWER TO THE CDSA, NOR DISCONNECT THE
USB CABLE, NOR TURN OFF THE PC DURING PROGRAMMING, OR ELSE YOUR
CDSA WILL NOT BE ABLE TO BOOT NORMALLY.
In case the programming has been interrupted accidentally, please follow the steps
below:
1. Turn off power to the CDSA via its back panel switch
2. Press and hold the Reset button on the back panel
3. Turn power back on. Release the Reset button only after the lights on the front
panel turn on.
4. Proceed as described under “Subsequent Upgrade Procedure”.
10