background image

3

Clock Section

INT / EXT:

Selects internal or external clock source. LOCK LED is lit 

when D/A converter is locked to external clock. When in 
INT, the DAC6e generates the master clock signal 
(master clock mode) for the audio source. Connect either 
the BNC or optical clock output from the DAC6 to your 
audio souce. 

When in EXT (slave clock mode) no additional 
connection from the DAC6e to the audio source is 
required.

Sample Rate Section

1FS / 2FS:

Selects the sample rate for PCM data. FS is the base 
frequency (see selector switch for base).

44.1 / 48:

Selects the base frequency (only 44.1kHz is allowed for 
DSD inputs)

Format Section

DSD / PCM:

Selects digital audio input format.

Phase Section

NORM / INV:

Selects normal or inverted phase.

Error Indicator Is lit for illegal switch positions

Basic Operation

Conversion from PCM on AES/EBU to Analog

Additional selections for 44.1 / 48 / 88.2 / 96kHz sample rate can be made 
with the sample rate switches.

48

INT

EXT

DSD

PCM

NORM

INV

FORMAT PHASE

1FS

2FS

LOCK

POWER

ERROR

44.1

SAMPLE CLOCK 

Reviews: