background image

4

Up to 3 AES/EBU cables can be connected to the DAC6e. The 4 possible 
audio frequencies can be selected according to Table 1:

In the case of 2FS operation (88.2kHz or 96kHz) the clock rate of the trans-

mission on the cable is double. Master / Slave clock operations can be 
selected with the INT / EXT switch (see below for more detail). In Slave 
operation there has to be at least an AES/EBU cable connected to channels 
1/2 as this connection provides the clock for the DAC6e.

Conversion from DSD on Optical to Analog

The optical interface format requires 2 cables: 1 for clock and 1 for audio 
data. They both need to be connected regardless of what clock mode is 
selected (master or slave). This mode requires the selection of 44.1kHz 
base frequency. Master / Slave clock operations can be selected with the 
INT / EXT switch (see below for more detail) and the 1FS / 2FS switch is 
ignored.

Table 1: Selection of Audio Sample Rates

Sample Rate

Switch

Switch

44.1kHz

1FS

44.1kHz

48kHz

1FS

48kHz

88.2kHz

2FS

44.1kHz

96kHz

2FS

48kHz

48

INT

EXT

DSD

PCM

NORM

INV

FORMAT PHASE

1FS

2FS

LOCK

POWER

ERROR

44.1

SAMPLE CLOCK 

Reviews: