Troubleshooting
IMPORTANT!
In the event of problems and in finding their causes, the applicable safety regulations must be observed.
Should disruptions/defects arise that are not mentioned in this manual, please contact our customer service team by
using the contact information on page 45.
Problems
Possible causes
Solutions
Pilot light does not go on
Gas valve may be closed
Open gas valve
Fuel cylinder empty
Fill LPG cylinder
Opening blocked
Clean or replace opening
Air in feed
Remove air from lines
Battery empty
Replace battery with same type
Pilot light goes out
Loose connection
Check all connections and tighten if
necessary
Dirt around the pilot light assembly
Clean the dirty area
Burner does not ignite
See also "Operating for first time" on page 40.
Defective heating element
Replace heating element
Leak in gas line
Check connections
Low gas pressure
Gas tank is almost empty
Opening blocked
Remove, clean and reattach
Regulator is not turned on
Turn valve to ON
Pilot light assembly is bent or not in the
proper position
Position the pilot light assembly correct-
ly and try again