9
TILTING PAN (GAS)
Kasap Tip Dik Buzdolapları
G
INJECTOR CHANGE AND GAS SETTING
GAS TILTING PANS BURNER-INJECTOR CHANGE CHART
Gas Group
Gas
DTG.50
DTG.80
DTG.120
Injector
mm
Injector
mm
Injector
mm
2
G20
2,5
3
3,5
G25
2,5
3
3,5
3
G30
30 mbar
1,40
2,5
2,5
50 mbar
1,40
2,5
2,5
G31
37 mbar
1,40
2,5
2,5
50 mbar
1,40
2,5
2,5
Change of Burner Injector
1. Rip off the injector at the entrance of burner with a suitable tool.
2. Change A injector by paying attention to the datas at chart with suitable injector.
(Image 1)
3. Adjust the burner
entrance setting (F) by loosening ‘B’ bolt and moving the valve to
forward-back. (Image 2)
4. Change C injector by paying attention to the datas at chart with suitable injector.For
this it is enough to take off ‘D’ fitting and pull the gas pipe to down. (Image 3)