                                                     FERMANTATION CABINET 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                        

 

 

Kasap Tip Dik Buz

dolapları 

 
 
 

SPARE PART LIST- EXPLODING DRAWING

 

 

PRODUCT CODE:  EMP.MFI.20 

NO 

PRODUCT NAME 

P.CODE 

BASE FRAME 

Y.EMP.MFI.20.001 

RESISTANCE 

Y.EMP.MFI.20.002 

FEET 

Y.EMP.MFI.20.003 

LID 

Y.EMP.MFI.20.004 

GLASS 

Y.EMP.MFI.20.005 

HINGE GROUP 

Y.EMP.MFI.20.006 

THERMOSTAT BUTTON 

Y.EMP.MFI.20.007 

CONTACTOR DILEM 01 

Y.EMP.MFI.20.008 

SWITCH BUTTON 

Y.EMP.MFI.20.009 

10 

SWITCH 0-1 

Y.EMP.MFI.20.010 

11 

WARNING LAMP (GREEN) 

Y.EMP.MFI.20.011 

12 

WARNING LAMP (RED) 

Y.EMP.MFI.20.012 

13 

THERMOSTAT 30-90 

Y.EMP.MFI.20.013 

14 

HANDLE 

Y.EMP.MFI.20.014 

15 

VESSEL  

Y.EMP.MFI.20.015 

16 

VESSEL SHEETMETAL  

Y.EMP.MFI.20.016 

17 

GASKET 

Y.EMP.MFI.20.017 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EMP.MF.20

Page 1: ...T DESCRIPTION Page 3 A2 TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 4 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G SPARE PART LIST EXPLODING DRAWING Page 9 H ELECTRIC CIRCUIT SCHEMA Page 17 ...

Page 2: ... disobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off the...

Page 3: ...Packaging Dimensions mm EMP MF 20 500X720X1800 80 1020x980x870 EMP MF 20 T 500X720X1800 83 1020x980x870 EMP MFI 20 630X850X1900 93 1150X1110X970 EMP MFI 20 T 630X850X1900 96 1150x1110X970 A2 TECHNICAL INFORMATION Product Code Capacity Electric Inlet V Cable mm Power KW Fuse A EMP MF 20 16 ad 40x60 220 3x2 5 3 16 EMP MF 20 T 16 ad 40x60 220 3x2 5 3 16 EMP MFI 20 16 ad 40x60 220 3x2 5 3 16 EMP MFI 2...

Page 4: ...ound please take necessary steps against possibility of overturn Technician who will serve for installation and service for the appliance must be professional on this subject and must have installation and service licenses by the company Connection to Electric Power Supply must be done by authorized person Please be sure that the voltage connected to appliance must be equal with the voltage which ...

Page 5: ...lammable material must be minimum 10 cm Do not operate the appliance when the machine is empty Do not load so less or more than appliance s capacity Do not attempt to use the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Neve...

Page 6: ... appliance and switch ON Add water to tank that is under the appliance When the resistance gets heated the fan starts to operate Switch the thermostat to 30 90 ºC according to dough s fermantation time Insert the trays that include the dough that will be fermented into the cabinet Take off the trays after fermantation process Switch OFF Unplug the appliance ...

Page 7: ...uter surface of the appliance with moist cloth Do not use abrasive cleaning chemicals as these can leave harmful residues Do not clean the appliance by spraying water directly otherwise electric motor may get damaged Do not clean the appliance with the materials that may damage to chrome material PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person Get the periodic main...

Page 8: ...k the heat settings 2 Check that if there is enough water at water tank or not THE APPLIANCE STOPPED 1 The appliance can stop due to low voltage In this situation check the voltage 2 Check the resistances When there is no water in the tank the resistances gets damaged If Dough Fermenting is not done at suitable quality If any function of security doesn t work Do not use the appliance If these prob...

Page 9: ...9 FERMANTATION CABINET Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWINGS EMP MF 20 ...

Page 10: ...5 GLASS Y EMP MF 20 005 6 HINGE GROUP Y EMP MF 20 006 7 THERMOSTAT BUTTON Y EMP MF 20 007 8 CONTACTOR DILEM 01 Y EMP MF 20 008 9 SWITCH BUTTON Y EMP MF 20 009 10 SWITCH 0 1 Y EMP MF 20 010 11 WARNING LAMP GREEN Y EMP MF 20 011 12 WARNING LAMP RED Y EMP MF 20 012 13 THERMOSTAT 30 90 Y EMP MF 20 013 14 HANDLE Y EMP MF 20 014 15 VESSEL Y EMP MF 20 015 16 VESSEL SHEETMETAL Y EMP MF 20 016 17 GASKET Y ...

Page 11: ...11 FERMANTATION CABINET Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWINGS EMP MF 20 T ...

Page 12: ... 6 HINGE GROUP Y EMP MF 20 T 006 7 THERMOSTAT BUTTON Y EMP MF 20 T 007 8 CONTACTOR DILEM 01 Y EMP MF 20 T 008 9 SWITCH BUTTON Y EMP MF 20 T 009 10 SWITCH 0 1 Y EMP MF 20 T 010 11 WARNING LAMP GREEN Y EMP MF 20 T 011 12 WARNING LAMP RED Y EMP MF 20 T 012 13 THERMOSTAT 30 90 Y EMP MF 20 T 013 14 HANDLE Y EMP MF 20 T 014 15 VESSEL Y EMP MF 20 T 015 16 VESSEL SHEETMETAL Y EMP MF 20 T 016 17 GASKET Y E...

Page 13: ...13 FERMANTATION CABINET Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP MFI 20 ...

Page 14: ... 20 004 5 GLASS Y EMP MFI 20 005 6 HINGE GROUP Y EMP MFI 20 006 7 THERMOSTAT BUTTON Y EMP MFI 20 007 8 CONTACTOR DILEM 01 Y EMP MFI 20 008 9 SWITCH BUTTON Y EMP MFI 20 009 10 SWITCH 0 1 Y EMP MFI 20 010 11 WARNING LAMP GREEN Y EMP MFI 20 011 12 WARNING LAMP RED Y EMP MFI 20 012 13 THERMOSTAT 30 90 Y EMP MFI 20 013 14 HANDLE Y EMP MFI 20 014 15 VESSEL Y EMP MFI 20 015 16 VESSEL SHEETMETAL Y EMP MFI...

Page 15: ...15 FERMANTATION CABINET Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP MFI 20 T ...

Page 16: ...FI 20 T 005 6 HINGE GROUP Y EMP MFI 20 T 006 7 THERMOSTAT BUTTON Y EMP MFI 20 T 007 8 CONTACTOR DILEM 01 Y EMP MFI 20 T 008 9 SWITCH BUTTON Y EMP MFI 20 T 009 10 SWITCH 0 1 Y EMP MFI 20 T 010 11 WARNING LAMP GREEN Y EMP MFI 20 T 011 12 WARNING LAMP RED Y EMP MFI 20 T 012 13 THERMOSTAT 30 90 Y EMP MFI 20 T 013 14 HANDLE Y EMP MFI 20 T 014 15 VESSEL Y EMP MFI 20 T 015 16 VESSEL SHEETMETAL Y EMP MFI ...

Page 17: ...7 FERMANTATION CABINET Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA I A1 T1 R1 FN Terminal Large lighted 0 1 switch Thermostat 30 90ºC Heater resistance 1000 W 230V Inner air circulation fan 230V ...