35646-2-0617
Page 6
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be per-
formed only by a qualified agency. The term "qualified agency" means
any individual, firm, corporation or company which either in person
or through a representative is engaged in and is responsible for (a)
the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
Commonwealth of Massachusetts:
The installation must be
made by a licensed plumber or gas fitter in the Commonwealth
of Massachusetts.
The installation and the provisions for combustion and ventilation
air must conform with the
National Fuel Gas Code, ANSI Z223.1
/
NFPA54* Canadian Installation Code
CAN/CGA B149.
*Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10018.
High Altitude Installation
When installing this unit at an elevation above 2000 feet (in the
United States) it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Generally,
input should be reduced 4 percent for each 1000 feet above sea
level. However, if the heating value of the gas has been reduced,
this general rule may not apply. Check with local gas utility for proper
orifice size identification.
For Canadian high altitude applications, this appliance is suitable for
installation at elevations between 0 feet (0m) and 4,500 (1,370m)
without change.
When installing this unit at an elevation above 4500 feet (1,370m)
(in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper
orifice for location.
GENERAL INFORMATION
• Turn off gas supply to fireplace or firebox.
• Have the fireplace floor and chimney professionally cleaned to
remove ashes, soot, creosote or other obstructions.
Have this cleaning performed annually after installation.
• Seal any fresh air vents or ash clean-out doors located on floor
or wall of fireplace. If not, drafting may cause pilot
outage or sooting. Use a heat-resistant sealant. Do not seal
chimney flue damper.
Installing Damper Clamp (Figure 2)
Remove all ashes or other debris from the fireplace. If the fireplace
is equipped with an ash dump be sure to seal the door with furnace
cement or high temperature silicone. Be sure to check the damper
for proper operation and verify that the flue passageway is open.
Attach damper clamp to the vent damper and tighten hold down bolt.
Place the clamp over the lip of the damper and tighten the hold
down bolt until the clamp is securely attached to the damper. This
will prevent the damper from accidentally closing.
Figure 2
FIREPLACE PREPARATION