40397-1-0719
Page 9
VARIABLE
Natural Gas
Propane Gas
Regulator
Pressure Setting
5.3"
10.0"
Gas Inlet
Pressure
Max.
10.5"
13.0"
Min.
6.0"
12.8"
Model
Gas
Type
Valve
Type
Orifice
Manifold
Pressure
(w.c.)
BTUH
Max.
Rate
BFE2124MTN Natural Variable
#22
5.3"
55,000
BFE30MTN
Natural Variable
#12
5.3"
65,000
BFE2124MTP
Propane
Variable
2.25mm
10.0"
55,000
BFE30MTP
Propane
Variable
#39
10.0"
65,000
PROPANE CONVERSION KIT
Burner Model
Valve Type
Kit Number
BFE2124MTN
Variable
CKV121
BFE30MTN
Variable
CKV122
NOTE:
The air shutter setting for all models is 1/16" open.
PRODUCT SPECIFICATIONS
DETERMINING THE CORRECT BURNER SIZE FOR YOUR
FIREPLACE
MINIMUM FIREPLACE DIMENSIONS
FACTORY BUILT FIREPLACES
Chimney Height Minimum of 10 Feet
Burner
Model
Log
Set
Size
Rear
Width
A
Depth
B
Front
Width
C
Height
D
Minimum
Vent
in Sq.
Inches
BFE2124MT(N,P)
24
26
16
30
20
49
BFE30MT(N,P)
30
30
16
36
20
49
FRON
T W
IDT
H
REAR
WIDT
H
CENTER
WIDT
H
DEPT
H
HEIGHT
A
B
C
D
E
Figure 1