11. Place batteries in receiver boxes and remotes using
instructions provided. Verify remote is communicating with
receiver.
Important! If installing a decorative front, an offset between the
finishing materials and fireplace opening is required. Refer to
the installation instructions provided with the decorative front for
more information.
For installation of the DFL601BL-1, DFL602BL, DFL721BL,
and DFL722BL kits, 1/2-inch unfinished space is required to
either side of the fireplace installation.
1/2”
1/2”
For installation of the DFL602NB & DFL722NB kits, 7/8-inch
unfinished space is required on all four sides of the fireplace
opening.
7/8”
7/8”
7/8”
7/8”
FIREPLACE
OPENING
FINISHED
WALL
NON-COMBUSTIBLE
BOARD INSTALLED
OVER APPLIANCE OPENING
Figure 47
NOTE: Standoffs and Non-Combustible Board shown for
reference
FIREPLACE
OPENING
STANDOFFS
NON-COMBUSTIBLE
TILE OR OTHER
MATERIAL
FRAMING
HEADER
FINISHED
WALL
NON-COMBUSTIBLE
BOARD INSTALLED
ON TOP OF FIREPLACE
FINISHED
WALL
NON-COMBUSTIBLE
TILE OR OTHER
MATERIAL
18-15/16”
11-3/4”
FRAMING
Figure 48
NOTE: Standoffs Brackets and Non-Combustible Board shown
for reference.
12. Install Non-Combustible Board (See Figure 47)
•
Do not attach non-combustible board to the fireplace. Attach
non-combustible board only to side studs, standoffs and
header board.
•
Predrill holes into non-combustible board and counter-sink.
•
For best results treat non-combustible board and area
around the board with Kilz prior to applying adhesive or
sealing compound.
•
Apply adhesive in joints between non-combustible board
panels.
•
Use only high-temperature adhesive and high-temperature
paints rated for minimum 300
o
F with the non-combustible
board.
13. Finish Wall
•
Use woven fiberglass joint tape and Durabond 45 joint
compound for best results when finishing non-combustible
panel and drywall joints around fireplace.
•
Tile or noncombustible materials can be applied on top of the
non-combustible board and finished wall as their instructions
require.
Notice for Finishing Materials
The wall above the fireplace will become hot. Install the non-
combustible board supplied with the fireplace before adding
paint, tile or stone. Attach tile or other non-combustible products
to the fireplace face and to the non-combustible area using
adhesives designed for high-temperature applications. Follow
the manufacturer's instructions for application and curing times.
Heat from the fireplace may cause incorrectly installed materials
to fail. If you are painting above the fireplace, use a coating
designed for high temperature environments and follow the
manufacturer's instructions for surface preparation, application
and curing. Heat from the fireplace may cause incorrectly
applied coatings to fail or discolor.
CAUTION
Failure to use a 300°F minimum adhesive may allow the
finishing material to fall.
FIREPLACE & NONCOMBUSTIBLE BOARD
INSTALLATION - FLUSH MOUNT