Page 8
36776-4-0117
PRODUCT SPECIFICATIONS
Table 1 - Air Shutter Opening - Natural Gas Models
Model
Air Shutter Opening
VFLL60FP90
1/16 inch
VFLL72FP90
1/16 inch
Table 2 - Air Shutter Opening - LP Gas Models
Model
Air Shutter Opening
VFLL60FP90
1/4 inch
VFLL72FP90
1/4 inch
VFLL60FP90LP
VFLL60FP90LN
VFLL72FP90LP
VFLL72FP90LN
Input BTU/HR Maximum
38,500
40,000
38,500
40,000
Input BTU/HR Minimum
31,000
25,000
31,000
25,000
Orifice
1.8mm
#32
1.8mm
#32
Notice
: Air shutter settings are factory set and muay not be altered.
GAS SUPPLY PRESSURES (inches water column)
GAS TYPE
MAXIMUM
MINIMUM
MANIFOLD
NAT
10.5
7.0
3.5
LP
13.0
11.0
10.0
HOMEOWNER REFERENCE INFORMATION
We recommend that you record the following information about your fireplace.
Model Number: _____________________________
Date purchased: ________________________
Serial Number: _____________________________
Location of fireplace:
_____________________
Dealer Name: ______________________________
Dealer Phone: _________________________
Notes: ______________________________________________________________________________
Summary of Contents for Boulevard VFLL60FP90LN-1