STANDING PILOT WIRING
STANDING PILOT WIRING DIAGRAM
Figure 22
For Standing Pilot Ignition Wiring: Appliance Requirements
WARNING
DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL
VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.
Optional Wall Switch
Position the wall switch in the desired position on a wall. Run a
maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum
wire and connect it to the fireplace valve pigtails.
WARNING
DO NOT CONNECT THE 110-120 VAC TO THE WALL SWITCH
OR THE CONTROL VALVE WILL BE DESTROYED.
WARNING
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROL. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not
cut or remove the groundig prong from this plug.