35657-4-1015
Page 9
FIREPLACE INSERT DIMENSIONS
When planning a fireplace insert installation, it’s necessary to
determine:
•
The vent system configuration to be used.
•
Gas supply piping.
•
Whether optional accessories - devices such as a wall switch
or remote control - are desired.
•
Electrical supply requirements for blower.
•
Proper opening size of fireplace required for installation of
the fireplace insert.
M
D
A
E
N
B
3"
3"
L
G
3 13/16"
K
I
6 1/16"
J
F
3 7/16"
INTAKE
3" Dia.
FLUE
3" Dia.
1 5/8"
H
C
Note:
6”, 1-piece
surround shown
A
D
C
B
Figure 1
Fireplace Opening Dimensional Information/Sizing
MINIMUM FIREPLACE OPENING DIMENSIONS
MODEL
NO.
HEIGHT
A*
FRONT
WIDTH
B
DEPTH
C
REAR
WIDTH
D
DV25IN
18-3/8”
27-1/2”
12-3/4”
17-1/4”
DV33IN
21-3/8”
30-1/2”
14-1/4”
19”
DV35IN
23-3/8”
33-1/2”
14-1/4”
22”
*
NOTICE
:
If the fireplace lintel is wider than 8” (203mm), the
height of the fireplace opening must be increased a few inches to
allow for a gradual offset in the exhaust and/or intake vent pipes.
DV FIREPLACE INSERT DIMENSIONS
MODEL
A
B
C
D
E
F
G
H
I
J
K
L
M
N
DV25IN
19-3/4”
28
14-1/2”
11-1/8”
25-1/4”
12-3/4”
17”
18-5/16”
27”
6-3/4”
9”
20”
25-5/8”
40”
DV33IN
22-3/4”
31
16
14-1/8”
28-1/4”
14-1/4”
18-3/4”
21-5/16”
30”
8-1/4”
10-1/2”
21-1/2”
28-5/8”
43”
DV35IN
24-3/4”
34
16
16-1/8”
31-1/4”
14-1/4”
21-3/4”
23-5/16”
33”
8-1/4”
10-1/2”
23”
30-5/8”
46”