Flush Wall Installation
Figure 14
Combustible Surround Installation
Figure 15
Attention:
Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform
to applicable insulation codes.
Vent Runs (Figures 16, 17, 18, 19 and 20)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL TERMINATION
Figure 16
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
DVCD(32,36)
47 ½”
(121 cm)
TO BOTTOM
OF UNIT
DVCD42
49 ½”
(126 cm)
TO BOTTOM
OF UNIT
INSTALLATION (continued)
FINISHED WALL
3” (76.2mm) OF NON-COMBUSTIBLE MATERIAL
FRONT TRIM OR
NON-COMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
FINISHED WALL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
3” (76.2mm) OF NON-COMBUSTIBLE MATERIAL