28365-2-0811
Page 26
PIPE LENGTH
WALL STRAP
CEILING FIRE STOP
90° ELBOW
90° ELBOW
OR
45° ELBOW
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
TWO 90 ELBOWS
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90 ELBOWS)
STORM COLLAR
ROOF FLASHING
Installing Vent Components (Figure 38)
Begin the vent system installation by installing the first Simpson
Duravent component, 90° elbow to the starting collars or straight
pipe on the top of the appliance, then the straight pipe length and
then horizontal or vertical termination kit.
noTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The
inner flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by sliding
the concentric pipe section with four (4) equally spaced interior beads
onto the appliance collar or previously installed component end with
four (4) equally spaced indented sections. When the internal beads
of each starting outer pipe line up, rotate pipe section clockwise 90°
(approximately 3 inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component
is securely fitted and locked into the preceding component in the
vent system.
Figure 38
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part
numbers and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers
DVVK-4FV
Vertical Flex Vent Kit 4" x 7"
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical, Includes SD-991,
SD-953, and SD-943
DVVK-4TP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8
to 11 inch wall thickness, Includes SD-911, SD-985,
SD-990 and SD-942
DVVK-4RP
(DVVK-4R)
Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall
thickness, (standard thru-the-wall venting) Includes SD-
908, SD-985 and SD-942
DVVK-4RE
Direct-Vent Fireplace Vent Kit for Rear Vent, Thru-the wall,
5 to 7 inch wall thickness, (standard thru-the-wall venting)
Includes SD-908, SD985 and SD-942
DVVK-4TSP
(DVVK-4TS)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5
to 7 inch wall thickness, Includes SD-908, SD-985,
SD-990 and SD-942
VIB6A
Vertical Inlet Baffle Kit for 6 5/8" diameter.
VIB7A
Vertical Inlet Baffle Kit for 7" diameter.
VENT SYSTEM IDENTIFICATION