OPTIONAL FIBER OR PORCELAIN LINERS
Liners are not required for this fireplace, but add to the ambience.
Order one liner for a peninsula and two for a see-through.
NOTICE:
•
This sequence may be used to install liners into either side
of the firebox.
•
The fiber or porcelain liner(s) must be installed prior to
installing the log set on the burner.
•
The fiber or porcelain liners sit in front (NOT behind) of the
brick brackets as shown in
Figures 61 and 62.
1. From either side of the fireplace, remove the lower access
panel.
2. The two glass spring-latches are on the bottom of the glass
frame. Release them by pulling them away from the fireplace
and down. Remove the screen frame and glass frame as a
unit (separating them is not necessary) by lifting them up and
away from the fireplace.
See Figure 60.
Figure 60
3. Set the brick bracket against the firebox wall as shown in
Figure 61.
Figure 61
4. Screw the brick bracket to the false floor (but do not tighten)
with the screws shown on the left side of
Figure 62
(Vent /
Pilot side liner only).
5. Use the self-drilling screws shown on the right side of
Figure
62
to attach the brick bracket to the firebox wall.
2
1
Figure 62
6. Tighten the screws installed in step 4. (Vent / Pilot side liner
only).
7. Attach a second brick bracket to the top of the firebox wall
using two sheet metal screws as shown in
Figure 63.
Figure 63
8. Set the bottom edge of the fiber or porcelain liner in front
of the bottom brick bracket (not behind) and tilt it into place
against the top brick bracket.
See Figure 64.
9. Secure the fiber or porcelain liner in place using the
remaining hand-formed retaining bracket. Form the bracket
as shown and fasten it to the firebox top using a self-drilling
screw.
See Figure 64.