SPECIFICATIONS
NATURAL GAS
LP
PENINSULA
MODELS
SEE-THRU
MODELS
PENINSULA
MODELS
SEE-THRU
MODELS
Input BTU/Hr Maximum
34,000
34,000
32,000
32,000
Input BTU/Hr Minimum
23,000
23,000
26,500
26,500
KWH (Maximum)
9.96
9.96
9.38
9.38
KWH (Minimum)
6.74
6.74
7.76
7.76
Orifice
#33
#33
#51
#51
Air Shutter Opening*
3/16in
(1/8in w/40ft. Vertical Vent,
flue restrictor installed)
3/16in
(1/8in w/40ft. Vertical Vent,
flue restrictor installed)
FULLY OPEN
FULLY OPEN
Height without standoff
39-1/2in
39-1/2in
39-1/2in
39-1/2in
Width
42-1/4in
45-1/2in
42-1/4in
45-1/2in
Depth
24in
24in
24in
24in
Gas Inlet Shutoff Valve (pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
Venting
5” x 8”, See Page 26
5” x 8”, See Page 26
5” x 8”, See Page 26 5” x 8”, See Page 26
*NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS SUPPLY PRESSURES
GAS TYPE
MAXIMUM
MINIMUM
MANIFOLD
NAT
14
4.5
3.5
LP
14
11
10