26988-3-1012
Page 7
Mantel Chart (Figure 3)
15”
(381mm)
TOP EDGE OF FIREPLACE
12” (305mm)
10” (254mm)
MANTEL
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
4”
5”
6”
7”
8”
9”
11”
13 3/4”
3/4”
1 ½”
2 1/4”
3”
3 3/4”
4 ½”
6”
8”
3”
Figure 3
Clearances (Figure 4)
Clearance from top front side of fireplace to ceiling is 36".
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
Note:
Island (C) and Room Divider (D)
installation is possible as long as the
horizontal portion of the vent system (H)
does not exceed 20 feet with a minimum
vertical run of 8 feet. See details in Venting
Section.
When you install your Direct Vent Fireplace
in (D) Room divider or (E) Flat on wall
corner positions, a minimum of 6 inches
clearance must be maintained from the
perpendicular wall and the front edge of
the appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note: When using Empire EMBF, UMC, and UMF Series Full Mantels
with ADVD32 and ADVD36 Series Fireplaces, combustible clearance
may be reduced to 1" clearance from top edge of fireplace face.
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NON-COMBUSTIBLE
FIRST 3
(SEE MAGNIFIED
VIEW)
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
”
CLEARANCES
LOCATING FIREPLACE
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
ISLAND
INSTALLATION