30369-18-0619
Page 27
Installation of Vertical Inlet Baffle
The vertical inlet baffle is to be used only in a completely vertical vent
installation. The vertical inlet baffle can be used when the vertical
vent rise is between 10 feet and 40 feet. To maintain the yellow
flame in the main burner, purchase Vertical Inlet baffle, DVF-139
from your Empire Comfort Systems, Inc. distributor or dealer for
Simpson Duravent only.
In a vertical vent rise the flame on the main burner can be reduced
due to the drawing action from the flue exhaust pipe and the air inlet
pipe. A decrease in the height or the appearance of the yellow flame
may occur when the vertical vent rise is between 10 feet and 40 feet.
To enhance the yellow flame on the main burner, the vertical inlet
baffle can be attached to the direct vent high wind vertical top.
Please use the following steps to install the vertical inlet baffle.
1. Place the vertical inlet baffle over the exterior of the air inlet
openings on the direct vent high wind vertical top.
2. There are three sections of air openings on the exterior of the
air inlet pipe.
To achieve the maximum amount of yellow flame the vertical
inlet baffle will cover-up three sections of air openings.
To achieve the minimum amount of yellow flame the vertical inlet
baffle will cover-up one section of air openings.
3.
Attach vertical inlet baffle to the direct vent high wind vertical top
with (2) 3/8" hex-head screws provided with vertical inlet baffle.
4. Installation of vertical inlet baffle is completed.
Parts List
Description
Part Number
quantity Supplied
Vertical Inlet Baffle
DVF-139
1
3/8" Hex-Head Screw
R-2656
2
Reassembly and Resealing vent Pipe System
Attach vent pipe to inlet and outlet vent adaptor on fireplace. Replace
the horizontal and vertical pipe lengths, elbows and horizontal or
vertical termination kit.
All vent system components lock into place by sliding the concentric
pipe section with four (4) equally spaced interior beads onto the
appliance collar or previously installed component end with four
(4) equally spaced indented sections. When the internal beads of
each starting outer pipe line up, rotate pipe section clockwise 90°
(approximately 3 inches). The vent pipe is now locked together.
Continue replacing components per the vent system configuration.
Be certain that each succeeding vent component is securely fitted
and locked into the preceding component in the vent system.
Reassembly and Resealing Gas Accumulation Relief System
Glass Frame Assembly and Combustion Chamber
Whenever the glass frame assembly is pivoted open by a delayed
ignition in the main burner, the glass frame assembly gaskets and
combustion chamber must be examined by a qualified service person
for damage. All damaged gaskets on the glass frame assembly and
combustion chamber must be replaced by a qualified service person.
If damage occurs to the combustion chamber, it must be replaced
by a qualified service person. Contact Empire Comfort Systems,
Inc. for replacement parts.
vertical Through the Roof Applications - See Figure 38
Your Gas Fireplace has been approved for:
a) Vertical installations up to 40 feet in height.
b) Two sets of 45-degree elbow offsets within these vertical
installations. From 0 to a maximum of 8 ft. a vent pipe can be
used between elbows.
c) Wall straps must be used to support offset pipe every 4'.
This application will require that you first determine the roof pitch
and use the appropriate venting components.
C
L
24” MINIMUM
CLEARANCE TO
COMBUSTIBLES;
NATURAL OR
MAN MADE.
TYPICAL ROOF
SUPPORT
TYPICAL JOIST
SUPPORT
40’
(12.19 M)
MAXIMUM
8’ (2.44 M)
MAXIMUM
8’ (2.44 M)
MAXIMUM
45°
45°
Figure 38
vERTICAL TERMINATION (CONT'D)