background image

FG10099-3-0214

Page 4

IMPORTANT SAFETY INFORMATION

WARNING: Follow all gas leak check procedures in this manual, 

prior to operation.
WARNING: Fuels used in gas or oil-fired appliances, and the 

products of combustion of such fuels, contain chemicals known to 

the State of California to cause cancer, birth defects, and/or other 

reproductive harm. This warning is issued pursuant to California 

Health & Safety Code Sec. 25249.6.  
While this appliance is not in use, the gas must be turned off at 

the gas supply.
DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS 

FITTING WHILE THIS APPLIANCE IS IN OPERATION.
NEVER leave the decorative gas log set unattended while in 

operation.
NEVER allow children to operate this decorative gas log set.
NEVER place hands or fingers on the front edge of this decora-

tive gas log set.
NEVER use liquid propane gas in a natural gas unit, or natural 

gas in a liquid propane unit.
DO NOT use solid-fuel or lighter fluid in any decorative gas log 

set.

Any safety screen or guard removed for servicing an appliance 

must be replaced prior to operating the appliance.

During manufacturing, fabrication, and shipping, various com-

ponents of this appliance are treated with certain oils, films, or 

bonding agents. These chemicals ARE NOT harmful, but may 

produce annoying smoke and smells, as they are burned off, 

during the initial operation of the appliance. This may possibly 

cause headaches, and eye or lung irritation. This is a normal 

and temporary occurrence. The initial break-in period should 

last three to four hours. During this period, provide maximum 

ventilation by opening a window or door, to allow odors to dis-

sipate. Any odor remaining after this initial break-in period, will 

be slight and will disappear with continued use.

PROPER CLEARANCES FROM COMBUSTIBLE CON-

STRUCTION AND MATERIALS MUST BE MAINTAINED 

FROM ALL SIDES, TOP, AND BOTTOM OF THIS APPLI-

ANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED NEAR ANY 

COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER 

ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
NEVER PLACE ANY COMBUSTIBLE MATERIAL WITHIN 

TWENTY-FOUR INCHES (24”)FROM THE FRONT OF THE 

FIREPLACE ENCLOSURE.

WARNING 

The damper clamp must be installed in a manner which will 

maintain the minimum permanent damper vent opening at all 

times. 

See Figure 1

. See the Decorative Gas Log Set Specifi-

cations on page 6.

Figure 1

WARNING

The State of Massachusetts requires that the chimney flue 

damper, when used with decorative gas log sets, be welded open 

or completely removed. In the Commonwealth of Massachusetts, 

this appliance must be installed by a licensed plumber or gasfit-

ter.

WARNING

Improper installation, adjustment, alteration, service or mainte-

nance, can cause property damage, personal injury or loss of life. 

Refer to the owner’s information manual, provided with this ap-

pliance. Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

Summary of Contents for METRO BMHK-18N-1

Page 1: ...ch can cause death or serious illness WARNING This appliance must be installed only in a solid fuel burning fireplace with a working flue and construction of noncombustible materials This unit is NOT...

Page 2: ...ICATIONS 6 INSTALLATION 7 12 FINAL SET UP 13 LIGHTING INSTRUCTIONS MATCH THROW UNITS 14 LIGHTING INSTRUCTIONS SAFETY PILOT UNITS 15 OPERATION 16 MAINTENANCE AND SERVICE 17 TROUBLESHOOTING 18 MASTER PA...

Page 3: ...e and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised...

Page 4: ...iance This may possibly cause headaches and eye or lung irritation This is a normal and temporary occurrence The initial break in period should last three to four hours During this period provide maxi...

Page 5: ...alls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could v...

Page 6: ...the ceramic logs and branches are cured SPECIFICATIONS MINIMUM FIREPLACE DIMENSIONS MASONRY BUILT FIREPLACES Chimney Height Minimum of 6 Feet LOG SET SIZE FRONT WIDTH IN INCHES DEPTH IN INCHES HEIGHT...

Page 7: ...e fireplace IMPORTANT Seal any fresh air vents or ash clean out doors located on the floor or wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resis...

Page 8: ...s stub and one wrench on the fitting remove the existing cap or gas jet assembly from the gas stub in the fireplace by turn ing the wrench on the gas cap in a counterclockwise direction 7 Clean the pi...

Page 9: ...ain outside of the fireplace and then place the entire assembly into the fireplace for final gas hook up Follow the instructions that are included with the valve pilot kit and or the instructions belo...

Page 10: ...ting included on some models to the gas stub 4 Using two adjustable wrenches and turning in a clockwise directions attach one end of the gas line to the brass re ducer fitting installed in the previou...

Page 11: ...e remote receiver FOR HANDHELD TRANSMITTER REMOTE RECEIVERS SEE FIGURES 12 14 FOR WALL SWITCH TRANSMITTER REMOTE RECEIVERS SEE FIGURES 15 17 WIRING SCHEMES FOR THE TERMINAL BLOCKS AND OP ERATIONS CHAR...

Page 12: ...R HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURES 13 14 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for direc tions on...

Page 13: ...y applied loose material em bers must be removed prior to reapplication CAUTION DO NOT place glowing embers sand vermiculite or lava rock cinders in the area of the safety pilot assembly 3 Remove all...

Page 14: ...as Match Throw Units can be lit by long hearth match hand fire starter or book match clip extender inserted near the center of the burner system 1 STOP Read the safety information above 2 Read all war...

Page 15: ...ove 2 Read all warnings and safety information in this manual WARNING BE SURE THAT THE CHIMNEY DAMPER IS FULLY OPEN 3 Push in the gas control knob slightly and turn it in a clockwise direction to the...

Page 16: ...place when this appliance is in operation Unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air WARNING When this decorative gas...

Page 17: ...make sure that the flue is drawing properly and that any vent pipe connections are tight 2 Check to see that there are no blockages at the chimney or vent termination 3 Check for creosote and soot bu...

Page 18: ...ow gas pressure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not...

Page 19: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 20: ...ROCK WOOL 5 FG10005 FG10005 FG10005 LAVA ROCK 6 FG10100 FG10100 FG10100 BRICK RISER 7 FG10097 FG10097 FG10097 GAS LINE METRO SERIES 14 INCH ALUMINUM 375 FLARE 8 FG10070 FG10070 FG10070 375 INCH FLARE...

Page 21: ...FG10099 3 0214 Page 21 PARTS VIEW...

Page 22: ...s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or...

Page 23: ...FG10099 3 0214 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...