background image

FG10099-3-0214

Page 5

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precautions 

which can protect both you and your family from an accident. 

Read them carefully now, then review them point by point with 

the members of your household. Someday when there may not 

be a minute to lose, everyone's safety will depend on knowing 

exactly what to do. If, after reading the following information, 

you feel you still need more information, please contact your 

gas supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas 

because of the odorant put in the LP-Gas. 

That’s your signal to go into immediate action!

• 

Do not operate electric switches, light matches, use your phone. 

Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.

•   LP-Gas is heavier than air and may settle in low areas such as 

basements. When you have reason to suspect a gas leak, keep 

out of basements and other low areas. Stay out until firefighters 

declare them to be safe.

•   Use your neighbor’s phone and call a trained LP-Gas service 

person  and  the  fire  department.  Even  though  you  may  not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

• 

 Finally,

 let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Some people cannot smell well. Some people cannot smell 

the odor of the chemical put into the gas. You must find out if 

you can smell the odorant in propane.

 Smoking can decrease 

your ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors in 

the area mask the gas odor. People may not smell the gas odor or 

their minds are on something else. Thinking about smelling a gas 

odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under some 

circumstances.

 For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants in 

LP-Gas also are subject to oxidation. This fading can occur if there 

is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into 

walls, masonry and other materials and fabrics in a room. That will 

take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

SAFETY INFORMATION FOR USERS OF LP-GAS

SOME POINTS TO REMEMBER

• 

Learn to recognize the odor of LP-gas.

 Your local LP-Gas 

Dealer can give you a “Scratch and Sniff” pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

• 

If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the odor 

if there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been out 

of service for a time may develop internal rust which will cause 

odor fade. If such conditions are suspected to exist, a periodic 

sniff test of the gas is advisable. 

If you have any question 

about the gas odor, call your 

LP-GAS dealer. A

 periodic 

sniff test of the LP-GAS is a good safety measure under 

any condition.

• 

If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

• 

If you experience a complete “gas out,” (the container is under 

no vapor pressure), turn the tank valve off immediately. If the 

container valve is left on, the container may draw in some air 

through openings such as pilot light orifices. If this occurs, some 

new internal rusting could occur. If the valve is left open, then 

treat the container as a new tank. Always be sure your con-

tainer is under vapor pressure by turning it off at the container 

before it goes completely empty or having it refilled before it is 

completely empty.

Summary of Contents for METRO BMHK-18N-1

Page 1: ...ch can cause death or serious illness WARNING This appliance must be installed only in a solid fuel burning fireplace with a working flue and construction of noncombustible materials This unit is NOT...

Page 2: ...ICATIONS 6 INSTALLATION 7 12 FINAL SET UP 13 LIGHTING INSTRUCTIONS MATCH THROW UNITS 14 LIGHTING INSTRUCTIONS SAFETY PILOT UNITS 15 OPERATION 16 MAINTENANCE AND SERVICE 17 TROUBLESHOOTING 18 MASTER PA...

Page 3: ...e and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised...

Page 4: ...iance This may possibly cause headaches and eye or lung irritation This is a normal and temporary occurrence The initial break in period should last three to four hours During this period provide maxi...

Page 5: ...alls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could v...

Page 6: ...the ceramic logs and branches are cured SPECIFICATIONS MINIMUM FIREPLACE DIMENSIONS MASONRY BUILT FIREPLACES Chimney Height Minimum of 6 Feet LOG SET SIZE FRONT WIDTH IN INCHES DEPTH IN INCHES HEIGHT...

Page 7: ...e fireplace IMPORTANT Seal any fresh air vents or ash clean out doors located on the floor or wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resis...

Page 8: ...s stub and one wrench on the fitting remove the existing cap or gas jet assembly from the gas stub in the fireplace by turn ing the wrench on the gas cap in a counterclockwise direction 7 Clean the pi...

Page 9: ...ain outside of the fireplace and then place the entire assembly into the fireplace for final gas hook up Follow the instructions that are included with the valve pilot kit and or the instructions belo...

Page 10: ...ting included on some models to the gas stub 4 Using two adjustable wrenches and turning in a clockwise directions attach one end of the gas line to the brass re ducer fitting installed in the previou...

Page 11: ...e remote receiver FOR HANDHELD TRANSMITTER REMOTE RECEIVERS SEE FIGURES 12 14 FOR WALL SWITCH TRANSMITTER REMOTE RECEIVERS SEE FIGURES 15 17 WIRING SCHEMES FOR THE TERMINAL BLOCKS AND OP ERATIONS CHAR...

Page 12: ...R HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURES 13 14 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for direc tions on...

Page 13: ...y applied loose material em bers must be removed prior to reapplication CAUTION DO NOT place glowing embers sand vermiculite or lava rock cinders in the area of the safety pilot assembly 3 Remove all...

Page 14: ...as Match Throw Units can be lit by long hearth match hand fire starter or book match clip extender inserted near the center of the burner system 1 STOP Read the safety information above 2 Read all war...

Page 15: ...ove 2 Read all warnings and safety information in this manual WARNING BE SURE THAT THE CHIMNEY DAMPER IS FULLY OPEN 3 Push in the gas control knob slightly and turn it in a clockwise direction to the...

Page 16: ...place when this appliance is in operation Unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air WARNING When this decorative gas...

Page 17: ...make sure that the flue is drawing properly and that any vent pipe connections are tight 2 Check to see that there are no blockages at the chimney or vent termination 3 Check for creosote and soot bu...

Page 18: ...ow gas pressure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not...

Page 19: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 20: ...ROCK WOOL 5 FG10005 FG10005 FG10005 LAVA ROCK 6 FG10100 FG10100 FG10100 BRICK RISER 7 FG10097 FG10097 FG10097 GAS LINE METRO SERIES 14 INCH ALUMINUM 375 FLARE 8 FG10070 FG10070 FG10070 375 INCH FLARE...

Page 21: ...FG10099 3 0214 Page 21 PARTS VIEW...

Page 22: ...s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or...

Page 23: ...FG10099 3 0214 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: