background image

12433-10-0109

Page 14

Parts can be ordered only through your 

service person or dealer

. For best results, the 

service person or dealer

 should order parts through 

the distributor. Parts can be shipped directly to the 

service person/dealer.

All parts listed in the 

Parts list

 have a 

Part number

. When ordering parts, first obtain the 

Model number

 from the name plate on your 

equipment. Then determine the 

Part number (not the index number) and the Description 

of each part from the following appropriate 

illustration and list. Be sure to give all this information.
Furnace Model Number 

    Part Description 

Furnace Serial Number  

  Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

empire comfort systems, inc.  nine eighteen Freeburg ave.   Belleville, il  62222-0529

  1 

TH-100 

WALL MOUNTING PLATE

  2 

TH-104 

GASKET - FOR WALL MOUNTING 

PLATE

  3 

TH-015 

AIR DROP ASSEMBLY - DV-210

  3 

TH-018 

AIR DROP ASSEMBLY - DV-215

  4 

11757 

OUTER CASING - DV-210

  4 

11758 

OUTER CASING - DV-215

  5 

TH-142 

INNER CASING  - DV-210

  5 

TH-143 

INNER CASING  - DV-215

  6 

TH-008 

FRONT PANEL  - DV-210

  6 

TH-009 

FRONT PANEL  - DV-215

  7 

TH-024 

COMBUSTION CHAMBER  - DV-210

  7 

TH-027 

COMBUSTION CHAMBER  - DV-215

  8 

712098 

GASKET - OBSERVATION HOLE COVER

  9 

DV-781 

OBSERVATION HOLE COVER 

  10 

DV-064 

COVER PLATE - OBSERVATION HOLE

  11 

852098 

NUT FOR ORIFICE FITTING

  12 

742134 

BURNER ORIFICE - DV-210 NAT

  12 

742133 

BURNER ORIFICE - DV-215 NAT

  12 

742297 

BURNER ORIFICE - DV-210 LPG

  12 

742282 

BURNER ORIFICE - DV-215 LPG

  13 

742038 

ORIFICE FITTING

  14 

732016 

ELECTRODE AND WIRE 

  15 

722049 

MANIFOLD

  16 

R-5598 

GAS VALVE 7000 MVRLC - NAT

  16 

R-5599 

GAS VALVE 7000 MVRLC - LPG

  17 

R-2890 

PILOT BURNER W/ORIFICE - LPG

  17 

R-2893 

PILOT BURNER WITH ORIFICE - NAT

  18 

TH-335 

PILOT SHIELD

  19 

712051 

GASKET - PILOT BURNER

  20 

TH-133 

CHAMBER DOOR WITH GASKET - DV-

210

  20 

TH-134 

CHAMBER DOOR WITH GASKET - DV-

215

  21 

TH-365 

VALVE BRACKET

  22 

TH-336 

PILOT TUBING - 1/4" (6.4mm) WITH 

FERRELLS

 (NAT.)

  22 

TH-367 

PILOT TUBING - 1/4" (6.4mm) WITH 

FERRELLS

 (LP)

  23 

672064 

THERMOPILE - GENERATOR

  24 

R-2708 

PIEZO IGNITOR

  25 

TH-289 

IGNITOR BRACKET

  26 

TH-275 

BURNER  - DV-210

  26 

24644 

BURNER  - DV-215

  27 

TH-109 

3" (76mm) DIA  FLUE OUTLET TUBE 

  28 

TH-107 

5" (127mm) DIA  AIR INLET TUBE 

  29 

TH-331 

OUTSIDE MOUNTING PLATE

  30 

TH-334 

VENT CAP 

  31 

TH-123 

VENT KIT COMPLETE 

  32 

R-5788 

WALL THERMOSTAT - MILLIVOLT

NOT SHOWN 

742158 

ORIFICE FOR PILOT - NAT

NOT SHOWN 

742266 

ORIFICE FOR PILOT - LPG

NOT SHOWN 

TH-300 

GASKET FOR CHAMBER DOOR - DV-

210

NOT SHOWN 

TH-281 

GASKET FOR CHAMBER DOOR - DV-

215

NOT SHOWN 

TH-351 

HARDWARE PACKAGE

NOT SHOWN 

652211 

REGULATOR - LPG

NOT SHOWN 

652121 

REGULATOR - NAT

NOT SHOWN 

922217 

OPERATOR - LPG

NOT SHOWN 

922113 

OPERATOR - NAT

  USE ONLY MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANY OTHER PARTS COULD CAUSE INjURY OR DEATH.

Please note:

  When ordering parts, it is very important that part number and description of part coincide.

INDEX 

PART

  NO. 

NUMBER 

DESCRIPTION

INDEX 

PART

  NO. 

NUMBER 

DESCRIPTION

HoW to orDer rePair Parts

Parts list

Summary of Contents for DV-210-SG

Page 1: ...th or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicin...

Page 2: ...ifications 6 Gas Supply 7 Clearances 8 Installation Instructions 8 9 Thermostat Location 10 Lighting Instructions 11 Pilot Flame Characteristics 12 Main Burner Flame Characteristics 12 Maintenance 12...

Page 3: ...ied service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is impera tive that control compartments burners and circulating air passageways...

Page 4: ...g vehicle trailer or area Finally let the service man and firefighters check for escaped gas Have them air out the area before you return Properly trained LP Gas service people should repair the leak...

Page 5: ...uiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the exter...

Page 6: ...erformed only by a qualified agency The term qualified agency meansanyindividual firm corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a the in...

Page 7: ...that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign partic...

Page 8: ...nimum wall depth is 4 1 2 114mm and maximum wall depth is 13 330mm The use of tubes not supplied by the manufacturer result in unsatisfactory performance The furnace is to be located on an outside wal...

Page 9: ...l Remove 5 127mm diameter air inlet tube from collar of air drop assembly 2 Attach3 76mm diameterflueoutlettubeontoflueoutletcollar oncombustionchamber Besure3 76mm diameterflueoutlet tube is placed a...

Page 10: ...d be Across the thermopile terminals 400 450 millivolts with ther mostat off Across the thermopile terminals 150 250 millivolts with ther mostat on Across the thermostat wires at the valve less than 3...

Page 11: ...to desired setting 16 CAUTION Pilot access cover must be kept tightly closed during operation To Turn Off Gas To Appliance FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these inst...

Page 12: ...ted After this the valve and orifice elbow can be removed as a unit Cleaning The Pilot Burner Cleaning of the pilot may be an annual necessity due to spiders After removing the supply tubing and orifi...

Page 13: ...properly size orifice 4 Pilot and main burner go out during normal operation a Check millivolts b Check for proper size of pilot flame c Check for defective or weak thermopile d Check input reduce as...

Page 14: ...HOLE 11 852098 NUT FOR ORIFICE FITTING 12 742134 BURNER ORIFICE DV 210 NAT 12 742133 BURNER ORIFICE DV 215 NAT 12 742297 BURNER ORIFICE DV 210 LPG 12 742282 BURNER ORIFICE DV 215 LPG 13 742038 ORIFICE...

Page 15: ...12433 10 0109 Page 15 PARTS VIEW...

Page 16: ...appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong re ceptacle Do not cut or remove th...

Page 17: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: