background image

32192-1-0314

Page 10

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Please Note: When ordering parts, it is very important that part number and description of part coincide.

Index 

No.

Part No.

Description

1

WFA115

BASEPLATE GASKET

2

11763

OUTER CASING TOP

3

R618

MOTOR MOUNT (FOUR REQUIRED)

4

11764

MOTOR MOUNTING BAR (TWO RE

-

QUIRED)

5

M147

GASKET (TWO REQUIRED)

6

R619

MOTOR

7

11787

FAN BLADE

8

DV635B

COMBUSTION CHAMBER

9

11766

FAN HOUSING

10

11759

SIDE PANEL

11

DV627

UPPER FRONT PANEL

12

R1619

BUSHING

13

DV823

DIVERTER ASSEMBLY

14

R1749

VENT SAFETY SWITCH

15

R1587

VENT SAFETY WIRE ASSEMBLY

16

R1536

BUSHING

17

11765

SWITCH COMPARTMENT ASSEMBLY

18

DV832

SWITCH COMPARTMENT COVER

19

R630

LIMIT CONTROL

20

R1941

FAN CONTROL

21

DV826

REAR BURNER

22

R685

THERMOCOUPLE

23

R622L

PILOT WITH ORIFICE LP GAS

23

R622N

PILOT WITH ORIFICE NATURAL GAS

24

DV808

PILOT TUBING

25

DV562

LOWER FRONT PANEL 

26

DV824

FRONT BURNER

27

P8842

MAIN BURNER ORIFICE NATURAL 

GAS (TWO REQUIRED)

27

P8853

MAIN BURNER ORIFICE LP GAS 

(TWO REQUIRED)

28

DV687

MANIFOLD AND PLATE ASSEMBLY

29

M148

MANIFOLD GASKET

30

DV064

COVER PLATE FOR OBSERVATION 

HOLE

31

DV622

BURNER DOOR NATURAL GAS

31

DV973

BURNER DOOR LP GAS

32

DV775

SEAL BRACKET

33

M147

GASKET TUBING SEAL

34

P112

MANIFOLD UNION

35

R5655

GAS VALVE VR8200C LP GAS

35

R2148

GAS VALVE VR8200C NATURAL GAS

36

UH810

TRANSFORMER MOUNTING BRACK

-

ET

37

R1995

TRANSFORMER

38

UH451

JUNCTION BOX COVER

39

DV974

OUTER CASING BOTTOM

40

R1515

BUSHING

41

R2708

PIEZO IGNITOR

42

R690

CORD SET

43

R896

BUSHING

44

DV671

MANIFOLD SUPPORT

45

DV765

GASKET FOR CHAMBER AIR INLET 

(TOP & BOTTOM) (2 REQUIRED)

46

DV764

GASKET FOR CHAMBER AIR INLET 

(SIDES) (TWO REQUIRED)

47

R1404

BUSHING

48

DV684

INNER LINING ASSEMBLY

49

DV629

CASING BACK

50

11759

SIDE PANEL

N/S

R9832

WIRE ASSEMBLY UPPER

N/S

R9833

WIRE ASSEMBLY LOWER

N/S

R734

LIGHTER ROD

N/S

742265

PILOT ORIFICE LP

N/S

R3469

PILOT ORIFICE NATURAL

N/S - Not Shown

Index 

No.

Part No.

Description

Summary of Contents for FAW-55-1SPP

Page 1: ...these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in...

Page 2: ...burner ignition devices are located not less than 18 457mm above the floor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehicle Specifications Model...

Page 3: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Page 4: ...onnected to a chimney flue serving a separate solid fuel burning appliance 3 Uninsulated Single Wall Metal Pipe shall not be used outdoors in cold climates for venting gas utilization equipment 4 Atte...

Page 5: ...connec tion Also refer to Figure 2 for positioning the furnace on wall and for locating gas line connection Locating Gas Supply The gas line can enter the furnace either though the floor or wall The...

Page 6: ...air in the gas line it is suggested that a match be used The match will light the pilot faster than the piezo under this condition Attention The 7 8 22mm strain relief bushing is located within the s...

Page 7: ...will be blue extending past the thermocouple The flame will surround the thermocouple just be low the tip Natural gas pilots require adjusting when the inlet gas pressure is above 5 w c 1 245kPa Remov...

Page 8: ...Fan Motor The upper front panel the shroud sur rounding the fan blade and fan blade must be removed See oiling the Motor paragraph on page 7 Spark Igniter Does Not Light Pilot With air in the gas lin...

Page 9: ...knob clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to...

Page 10: ...808 PILOT TUBING 25 DV562 LOWER FRONT PANEL 26 DV824 FRONT BURNER 27 P8842 MAIN BURNER ORIFICE NATURAL GAS TWO REQUIRED 27 P8853 MAIN BURNER ORIFICE LP GAS TWO REQUIRED 28 DV687 MANIFOLD AND PLATE ASS...

Page 11: ...32192 1 0314 Page 11...

Page 12: ...oval elbows 3 Single story type B 1 gas vents require a baseplate and one pair of ceiling plate spacers 4 Multi story type B 1 gas vents require a baseplate one pair of ceiling plate spacers at the fi...

Page 13: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 14: ...32192 1 0314 Page 14 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 15: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Page 16: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Page 17: ...tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez a aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b ti ment o vous...

Page 18: ...syst me de com mande et les commandes de gaz qui ont t en contact avec l eau Ce radiateur ne doit pas tre branch une chemin e servant un autre appareil br lant un combustible solide A cause des hautes...

Page 19: ...que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas ouvrir les so...

Page 20: ...tall s dans un endroit o la facilit delaventilationpermetunecombustiondegazsatisfaisanteetun chappe ment convenable sous des conditions normales Dans les b timents de construction conventionnelle de b...

Page 21: ...tant est chang de place Un guide est fourni dans l emballage du radiateur pour vous aider localiser la connexion pour la ligne de gaz Aussi r f rer la Figure 2 pour positionner le radiateur sur le mur...

Page 22: ...de 3 914mm du compartiment des contr les au bas du radiateur 2 Enlever l entr e d fon able de 7 8 22mm du c t du panneau ap propri 3 Introduire le bouchon de nylon de l assemblage de la fiche de 3 914...

Page 23: ...que le radiateur ait fonctionn il se peut que les ouvertures du br leur soient bloqu es par des mati res trang res venant de l air de combustion Donc un nettoyage du br leur peut tre exig pour obteni...

Page 24: ...ation lequel doit tre install et entretenu correctement ou lorsque vous tripotez avec le syst me de fermeture de s ret de l vent peut causer un empoissonnement au monoxide de carbone CO et possiblemen...

Page 25: ...tion La veilleuse est suppos e rester allumer Si elle s teint recommencer les tapes 5 jusqu 10 Si le bouton ne revient pas sa position lorsque vous le rel chez arr ter et appeler imm diatement un tech...

Page 26: ...intervalles jusqu ce qu elle s allume Si l lectrode ne Produit Pas d tincelle 1 V rifier les connexions des fils lectriques 2 V rifier la distance du br leur de la veilleuse au bout de l lectrode Doi...

Page 27: ...s ret de l vent 16 8720130 Manchon 17 11765 Assemblage du compartiment d interrupteur 18 DV 832 Couvercle du compartiment d interrupteur 19 912073 Contr le de tol rance 20 R 1941 Contr le du ventilat...

Page 28: ...12428 7 0314 Page 12 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529...

Page 29: ...de base et une paire d entretoises pour la plaque du plafond 4 Les vents gaz de type B 1 pour plus d un tage exige une plaque de base une paire d entretoises pour la plaque du pla fond au plafond du...

Page 30: ...mages pouvant r sulter de l emploi de l emploi abusif ou d une installation incorrecte de cet appareil Frais de d placement de diagnostic et de transport des pi ces sous garantie vers et depuis l usin...

Reviews: