background image

Page 1

INSTALLATION INSTRUCTIONS

AND

OWNER’S MANUAL

WARNING: If not installed, operated and main-

tained  in  accordance  with  the  manufacturer’s  

instructions,  this  product  could  expose  you  to 

substances in fuel or from fuel combustion which 

can cause death or serious illness.

FAN TYPE

VENTED

WALL FURNACE

MODEL

FAW-55SPP

Installer:  Leave this manual with the appli-

ance.

Consumer: Retain this manual for future refer-

ence.

—  Do not store or use gasoline or other flamma-

ble vapors and liquids in the vicinity of this or 

any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately call your gas supplier from a 

neighbor’s  phone.  Follow  the  gas  suppli-

er’s instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

—  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING: If the information in these instruc-

tions are not followed exactly, a fire or explosion 

may result causing property damage, personal 

injury or loss of life.

Summary of Contents for FAW-55SPP

Page 1: ...or other amma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any pho...

Page 2: ...ocated not less than 18 457mm above the oor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehicle Speci cations Model FAW 55SPP Input BTU HR KW H 55...

Page 3: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 4: ...age of ue products due to improper venting the vent safety switch will open which results in State of Massachusetts The installation must be made by a licensed plumber or gas tter in the Commonwealth...

Page 5: ...Gas Supply The gas line can enter the furnace either though the oor or wall The gas line opening should be made at this time Location of the opening will be determined by the position of oor joists a...

Page 6: ...Insert 7 8 22mm strain relief bushing into the 7 8 22mm hole in the side panel Attention The7 8 22mm strainreliefbushingislocatedwithinthesame yellow envelope as the Installation Instructions and Own...

Page 7: ...pilot ame Figure 6 will be blue extending past the thermo couple The ame will surround the thermocouple just below the tip Natural gas pilots require adjusting when the inlet gas pressure is above 5...

Page 8: ...Main Burner Ori ces Disconnect the gas supply at the inlet to the control valve Then remove the burner door to which the above compo nents are attached Servicing The Fan Motor The upper front panel t...

Page 9: ...ontrol knob clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the oor If you smell gas STOP Fol low B in the safety information above If you don t smell gas...

Page 10: ...59 GASKET TUBING SEAL 7 11787 FAN BLADE 34 722040 MANIFOLD UNION 8 DV 635 B COMBUSTION CHAMBER 35 R 5655 GAS VALVE VR8200C LP GAS 9 11766 FAN HOUSING 35 R 2148 GAS VALVE VR8200C NATURAL GAS 10 11759 S...

Page 11: ...12428 6 0408 Page 11...

Page 12: ...re a baseplate one pair of ceiling plate spacers at the rst oor ceiling and one pair of re stop spacers at each successive ceiling level Stud space around gas vents must be free of obstructions and bu...