SPECIFICATIONS
Models
PVS18(N,P)
PVS35(N,P)
Maximum Input BTU/HR (KW/H)*
17,500 (5.13)
35,000 (10.26)
Minimum Input BTU/HR (KW/H)*
8,750 (2.56)
17,500 (5.13)
Height
27-7/8”
27-7/8”
Width
36-1/8”
36-1/8”
Depth with Shroud**
13
13
Gas Inlet (Pipe)
3/8” Pipe
3/8” Pipe
Electrical - The wall furnace comes equipped with a 5 foot (1.5m) 3 pronged cord exiting the rear left side of the wall furnace, for
connection to an approved 115 VAC, 60 Hz, 15A (maximum) wall receptacle. The Minimum Circuit Amp (MCA) is 8A, 920W and with
an accessory heated humidification tray installed, the MCA is 10A, 1150W.
Vent Pipe: 1-1/2 or 2 inch diameter pipe, 50 feet maximum equivalent length. See pages 26 and 29 to 32. The vent termination elbow
does not contribute to the overall vent length measurement.
* Input ratings are based on sea level operation and may vary at different elevations. No orifice change is required. The appliance will
de-rate automatically 1.5% per 1,000 feet.
** Add 3-3/8 inches for deep shroud.
All vent and combustion air pipes and fittings must be Schedule 40 PVC, ULC S636 and meet the ANSI/ASTM Standard D1785. Cement
must conform to ASTM Standard D2564. Empire-approved poly pipe with gasketed joints may also be used. Contact your Empire dealer
for availability.
Listed for Category IV venting.
INTRODUCTION
SPECIFICATIONS AND DIMENSIONS
Dimensions - Figure 22
Approved Alternate Vent Systems
Manufacturer
Vent System
Duravent
PolyPro
Centrotherm
InnoFlue
Summary of Contents for PVS18N-3
Page 7: ...37873 0 0217 Page 7 OWNER S MANUAL AND OPERATION INSTRUCTIONS www empirezoneheat com...
Page 13: ...37873 0 0217 Page 13 INSTALLATION INSTRUCTIONS www empirezoneheat com...
Page 55: ...37873 0 0217 Page 7 GUIDE D UTILISATION ET INSTRUCTIONS D INSTALLATION www empirezoneheat com...
Page 61: ...37873 0 0217 Page 13 INSTRUCTIONS D INSTALLATION www empirezoneheat com...