INITIAL STARTUP AND ADJUSTMENTS
WALL FURNACE INSTALLATION
The table below outlines the BTU input rate of the wall furnace for
each flame level.
Heat Level
BTU Input
Single Tube
BTU Input
Double Tube
5 (HI)
17,500
35,000
4
15,350
30,700
3
13,150
26,300
2
10,950
21,900
1 (LO)
8,750
17,500
Table 4
7. After 45 to 70 seconds, the circulating air blower will acti-
vate. The circulating air blower speed will be set by the heat
level and will display on the Display Panel.
See Figure 62.
Figure 62
Display Backlight
The display panel backlight will automatically turn off five sec
-
onds after an input (either manual or remote) is acknowledged.
The backlight will automatically turn on when a new input is
acknowledged. To turn the backlight on manually, press the “Back-
light” button on the bottom left of the display panel.
See Figure
24, page 18.
Shut Down Instructions
To off turn the wall furnace, simply set the thermostat to a set-
ting below the room temperature or push the display panel’s mode
select button to “OFF”. See Figure 15, page 11. DO NOT cut the
main electrical power to the wall furnace.
The circulating air blower will continue to operate after the burner
is turned off. The blower will stop automatically after 100 to 160
seconds to ensure the wall furnace has cooled sufficiently.
Checking Manifold Pressure
Both Propane and Natural gas valves have a built-in pressure
regulator in the gas valve. See page 23 for a list of the normal high
and low manifold pressures.
A pressure tap accessible for test gauge connection is located on
the outlet side of the gas control.
Blower Operation
The circulating air blower will automatically engage and increase
in speed depending on the heat level. The circulating air blower
will start 45 to 70 seconds after ignition of the burner.
Once the wall furnace is turned off or the call for heat has been
satisfied, the circulating air blower will continue to run. The blower
will automatically turn off 100 to 160 seconds after the wall furnace
turns off to ensure proper cooling of the wall furnace.
Summary of Contents for PVS18N-3
Page 7: ...37873 0 0217 Page 7 OWNER S MANUAL AND OPERATION INSTRUCTIONS www empirezoneheat com...
Page 13: ...37873 0 0217 Page 13 INSTALLATION INSTRUCTIONS www empirezoneheat com...
Page 55: ...37873 0 0217 Page 7 GUIDE D UTILISATION ET INSTRUCTIONS D INSTALLATION www empirezoneheat com...
Page 61: ...37873 0 0217 Page 13 INSTRUCTIONS D INSTALLATION www empirezoneheat com...