background image

Page 1

INSTALLATION 

INSTRUCTIONS

CAST IRON BLOWER

CIB3-3

FOR USE ON:

EMPIRE CAST IRON STOVES 

MODELS:

DVP30CA30(B,F,M,S,W)(N,P)

DVP30CC(30,70)(B,F,M,S,W)(N,P)

VFP30CA30(B,F,M,S,W)(N,P)

VFD30CC(30,70)(B,F,M,S,W)(N,P)

Carton Contents

Blower Assembly

Auto/On/Off Switch

Fan Control Bracket Assembly

Hardware Package

 

(2) 10 x 1/2” Screw

 

(1) On/Off/Auto Switch

 

(1) Rheostat Nut

 

(1) Knob, Rheostat

Hardware Package

CAUTION: Sharp edges, use protective gloves when  

installing.

LEAVE THIS MANUAL WITH THE OWNER FOR FUTURE REFERENCE.

NUT

KNOB

#10 x 1/2” SCREW

AUTO/ON/OFF SWITCH

Installing Optional CIB3 Blower

1.  Loosen, but do not remove, four hex-head screws located on 

the exterior, bottom of the appliance.

2.  Position the blower assembly at the rear of the appliance. 

The blower assembly has four keyholes for attachment to the 

exterior, bottom of the appliance.

3.  Place the large diameter holes in the keyholes over and behind 

the four hex-head screws that were loosened in Step 1. Push 

inward on the blower assembly to lock the keyholes into position 

behind the screws. Tighten four hex-head screws to secure 

blower assembly to exterior, bottom of the appliance.

4.  Remove wire channel-left from appliance by removing two  

10 x 1/2" screws on left side of the appliance. 

5.  Route fan control wires through rectangular notch on wire 

channel - left.

6.  Attach 1/4" push-on terminal from blue wire on the fan control 

to the AUTO (top) tab on the switch.

7.  Attach 1/4" push-on terminal from black wire to the OFF (middle) 

tab on the switch.

8.  Attach 1/4" push-on terminal from white wire on the fan control 

to the ON (bottom) tab on the switch.

9.  Insert AUTO/OFF/ON switch into rectangular notch on  wire 

channel - left.

10.  Install rheostat through hole in wire channel and align small 

tab with small hole.

11.  Use an 11/16” wrench to tighten rheostat nut on stationary 

12.  Push rheostat knob onto knob stem until fully seated.

13.  Bend the fan control tab, located on the left side of the back 

of the unit, inward toward the unit. See Figure 1. Be sure tab 

is bent at least 90 degrees to allow fan control bracket to slide 

into slot. 

14. Attach fan control with bracket onto rear cover with  

two (2) 10 x 1/2" screws provided in hardware package.

15.  Route wires from fan control and ON/OFF/REMOTE switch 

within wire channel.

16.  Attach wire channel with two 10 x 1/2" screws from Step 4.  

17.  Installation of optional CIB3 blower is completed.

GAS-FIRED