36167-1-0316
Page 10
CLEARANCES
Clearance to Combustibles
Dim. in inches
Back
0
Side
0
Floor
0
Top Stand-off
0
Top Framing edge
0
BARRIER SCREEN
&
GLASS FRONT
2" x 4" BOTTOM PLATE
INSTALLED
NAILING
FLANGES
STAND OFF
6” (76mm) HEIGHT
ABOVE TOP OF
FIREPLACE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTEL CHART FOR
MAXIMUM MANTEL DEPTH
SEE MANTEL CHART FOR
MINIMUM HEIGHT OF
MANTEL ABOVE HOOD
FINISHED WITH
NON-COMBUSTIBLE
MATERIAL AS DESIRED
figure 5
NOTICE:
If applicable,
use only non-combustible materials to
finish the face of the fireplace.
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace or its mantel. The flow of
heat can ignite combustibles.
FIREPLACE
(TOP VIEW)
FRONT
FACE
(SIDE)
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
3
MAX.
6
PERPENDICULAR
SIDE WALL
45°
HOOD
figure 6
Mantel Chart
CANOPY
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
FLOOR
WALL
FACING
A
B
C
D
E
F
10”
20 1/4”
MIN.
10 1/4”
MIN.
41”
MIN.
COMBUSTIBLES
ALLOWED
WALL
STUD
TOP OF CANOPY
Index
Letter
Distancefrom
Wall facing
Distance from
Top of Canopy
Dimensions in inches
A
2
10-1/4
B
4
12-1/4
c
6
14-1/4
d
8
16-1/4
e
10
18-1/4
f
12
20-1/4
figure 7
Clearances
Clearance from top of canopy of fireplace to ceiling is 41
inches.
Clearance from side of fireplace to adjacent sidewall is 6
inches
.
41” (91.4 mm)
MINIMUM
6” (152 mm)
MINIMUM
figure 8